Gynecomastia is characterized by the enlargement of male breasts, which is a common and sometimes distressing condition found in over half of adult men over the age of 44. Although the majority of gynecomastia is physiologic or idiopathic, its occurrence may also associate with an extensive variety of underlying systemic disease or drug toxicity. With the recent large-scale implementation of annual lung cancer screening using low-dose chest CT (LDCT), gynecomastia is believed to be a frequent incidental finding on LDCT. A fully automated system for gynecomastia quantification from LDCT is presented in this paper. The whole breast region is first segmented using an anatomyorientated approach based on the propagation of pectoral muscle fronts in the vertical direction. The subareolar region is then localized, and the fibroglandular tissue within it is measured for the assessment of gynecomastia. The presented system was validated using 454 breast regions from non-contrast LDCT scans of 227 adult men. The ground truth was established by an experienced radiologist by classifying each breast into one of the five categorical scores. The automated measurements have been demonstrated to achieve promising performance for the gynecomastia diagnosis with the AUC of 0.86 for the ROC curve and have statistically significant Spearman correlation r=0.70 (p < 0.001) with the reference categorical grades. The encouraging results demonstrate the feasibility of fully automated gynecomastia quantification from LDCT, which may aid the early detection as well as the treatment of both gynecomastia and the underlying medical problems, if any, that cause gynecomastia.
A fully automated system is presented for bone mineral density (BMD) assessment from low-dose chest CT (LDCT). BMD assessment is central in the diagnosis and follow-up therapy monitoring of osteoporosis, which is characterized by low bone density and is estimated to affect 12.3 million US population aged 50 years or older, creating tremendous social and economic burdens. BMD assessment from DXA scans (BMDDXA) is currently the most widely used and gold standard technique for the diagnosis of osteoporosis and bone fracture risk estimation. With the recent large-scale implementation of annual lung cancer screening using LDCT, great potential emerges for the concurrent opportunistic osteoporosis screening. In the presented BMDCT assessment system, each vertebral body is first segmented and labeled with its anatomical name. Various 3D region of interest (ROI) inside the vertebral body are then explored for BMDCT measurements at different vertebral levels. The system was validated using 76 pairs of DXA and LDCT scans of the same subject. Average BMDDXA of L1-L4 was used as the reference standard. Statistically significant (p-value < 0.001) strong correlation is obtained between BMDDXA and BMDCT at all vertebral levels (T1 – L2). A Pearson correlation of 0.857 was achieved between BMDDXA and average BMDCT of T9-T11 by using a 3D ROI taking into account of both trabecular and cortical bone tissue. These encouraging results demonstrate the feasibility of fully automated quantitative BMD assessment and the potential of opportunistic osteoporosis screening with concurrent lung cancer screening using LDCT.
A three-dimensional (3-D) convolutional neural network (CNN) trained from scratch is presented for the classification of pulmonary nodule malignancy from low-dose chest CT scans. Recent approval of lung cancer screening in the United States provides motivation for determining the likelihood of malignancy of pulmonary nodules from the initial CT scan finding to minimize the number of follow-up actions. Classifier ensembles of different combinations of the 3-D CNN and traditional machine learning models based on handcrafted 3-D image features are also explored. The dataset consisting of 326 nodules is constructed with balanced size and class distribution with the malignancy status pathologically confirmed. The results show that both the 3-D CNN single model and the ensemble models with 3-D CNN outperform the respective counterparts constructed using only traditional models. Moreover, complementary information can be learned by the 3-D CNN and the conventional models, which together are combined to construct an ensemble model with statistically superior performance compared with the single traditional model. The performance of the 3-D CNN model demonstrates the potential for improving the lung cancer screening follow-up protocol, which currently mainly depends on the nodule size.
With the advent of fully automated image analysis and modern machine learning methods, there is a need for very large image datasets having documented segmentations for both computer algorithm training and evaluation. This paper presents a method and implementation for facilitating such datasets that addresses the critical issue of size scaling for algorithm validation and evaluation; current evaluation methods that are usually used in academic studies do not scale to large datasets. This method includes protocols for the documentation of many regions in very large image datasets; the documentation may be incrementally updated by new image data and by improved algorithm outcomes. This method has been used for 5 years in the context of chest health biomarkers from low-dose chest CT images that are now being used with increasing frequency in lung cancer screening practice. The lung scans are segmented into over 100 different anatomical regions, and the method has been applied to a dataset of over 20,000 chest CT images. Using this framework, the computer algorithms have been developed to achieve over 90% acceptable image segmentation on the complete dataset.
The segmentation and labeling of the individual bones serve as the first step to the fully automated measurement of skeletal characteristics and the detection of abnormalities such as skeletal deformities, osteoporosis, and vertebral fractures. Moreover, the identified landmarks on the segmented bone structures can potentially provide relatively reliable location reference to other non-rigid human organs, such as breast, heart and lung, thereby facilitating the corresponding image analysis and registration. A fully automated anatomy-directed framework for the segmentation and labeling of the individual bone structures from low-dose chest CT is presented in this paper. The proposed system consists of four main stages: First, both clavicles are segmented and labeled by fitting a piecewise cylindrical envelope. Second, the sternum is segmented under the spatial constraints provided by the segmented clavicles. Third, all ribs are segmented and labeled based on 3D region growing within the volume of interest defined with reference to the spinal canal centerline and lungs. Fourth, the individual thoracic vertebrae are segmented and labeled by image intensity based analysis in the spatial region constrained by the previously segmented bone structures. The system performance was validated with 1270 lowdose chest CT scans through visual evaluation. Satisfactory performance was obtained respectively in 97.1% cases for the clavicle segmentation and labeling, in 97.3% cases for the sternum segmentation, in 97.2% cases for the rib segmentation, in 94.2% cases for the rib labeling, in 92.4% cases for vertebra segmentation and in 89.9% cases for the vertebra labeling.
Breast cancer is the most common cancer diagnosed among US women and the second leading cause of cancer death 1 . Breast density is an independent risk factor for breast cancer and more than 25 states mandate its reporting to patients as part of the lay mammogram report 2 . Recent publications have demonstrated that breast density measured from low-dose chest CT (LDCT) correlates well with that measured from mammograms and MRIs 3-4 , thereby providing valuable information for many women who have undergone LDCT but not recent mammograms. A fully automated framework for breast density assessment from LDCT is presented in this paper. The whole breast region is first segmented using an anatomy-orientated novel approach based on the propagation of muscle fronts for separating the fibroglandular tissue from the underlying muscles. The fibroglandular tissue regions are then identified from the segmented whole breast and the percentage density is calculated based on the volume ratio of the fibroglandular tissue to the local whole breast region. The breast region segmentation framework was validated with 1270 LDCT scans, with 96.1% satisfactory outcomes based on visual inspection. The density assessment was evaluated by comparing with BI-RADS density grades established by an experienced radiologist in 100 randomly selected LDCT scans of female subjects. The continuous breast density measurement was shown to be consistent with the reference subjective grading, with the Spearman’s rank correlation 0.91 (p-value < 0.001). After converting the continuous density to categorical grades, the automated density assessment was congruous with the radiologist’s reading in 91% cases.
A fully-automated computer algorithm has been developed to identify early-stage Usual Interstitial Pneumonia (UIP) using features computed from low-dose CT scans. In each scan, the pre-segmented lung region is divided into N subsections (N = 1, 8, 27, 64) by separating the lung from anterior/posterior, left/right and superior/inferior in 3D space. Each subsection has approximately the same volume. In each subsection, a classic density measurement (fractional high-density volume h) is evaluated to characterize the disease severity in that subsection, resulting in a feature vector of length N for each lung. Features are then combined in two different ways: concatenation (2*N features) and taking the maximum in each of the two corresponding subsections in the two lungs (N features).
The algorithm was evaluated on a dataset consisting of 51 UIP and 56 normal cases, a combined feature vector was computed for each case and an SVM classifier (RBF kernel) was used to classify them into UIP or normal using ten-fold cross validation. A receiver operating characteristic (ROC) area under the curve (AUC) was used for evaluation. The highest AUC of 0.95 was achieved by using concatenated features and an N of 27. Using lung partition (N = 27, 64) with concatenated features had significantly better result over not using partitions (N = 1) (p-value < 0.05). Therefore this equal-volume partition fractional high-density volume method is useful in distinguishing early-stage UIP from normal cases.
A fully automated computer algorithm has been developed to evaluate coronary artery calcification (CAC) from lowdose CT scans. CAC is identified and evaluated in three main coronary artery groups: Left Main and Left Anterior Descending Artery (LM + LAD) CAC, Left Circumflex Artery (LCX) CAC, and Right Coronary Artery (RCA) CAC. The artery labeling is achieved by segmenting all CAC candidates in the heart region and applying geometric constraints on the candidates using locally pre-identified anatomy regions. This algorithm was evaluated on 1,359 low-dose ungated CT scans, in which each artery CAC content was categorically visually scored by a radiologist into none, mild, moderate and extensive. The Spearman correlation coefficient R was used to assess the agreement between three automated CAC scores (Agatston-weighted, volume, and mass) and categorical visual scores. For Agatston-weighted automated scores, R was 0.87 for total CAC, 0.82 for LM + LAD CAC, 0.66 for LCX CAC and 0.72 for RCA CAC; results using volume and mass scores were similar. CAC detection sensitivities were: 0.87 for total, 0.82 for LM + LAD, 0.65 for LCX and 0.74 for RCA. To assess the impact of image noise, the dataset was further partitioned into three subsets based on heart region noise level (low<=80HU, medium=(80HU, 110HU], high>110HU). The low and medium noise subsets had higher sensitivities and correlations than the high noise subset. These results indicate that location specific heart risk assessment is possible from low-dose chest CT images.
With the advent of modern machine learning methods and fully automated image analysis there is a need for very large image datasets having documented segmentations for both computer algorithm training and evaluation. Current approaches of visual inspection and manual markings do not scale well to big data. We present a new approach that depends on fully automated algorithm outcomes for segmentation documentation, requires no manual marking, and provides quantitative evaluation for computer algorithms. The documentation of new image segmentations and new algorithm outcomes are achieved by visual inspection. The burden of visual inspection on large datasets is minimized by (a) customized visualizations for rapid review and (b) reducing the number of cases to be reviewed through analysis of quantitative segmentation evaluation. This method has been applied to a dataset of 7,440 whole-lung CT images for 6 different segmentation algorithms designed to fully automatically facilitate the measurement of a number of very important quantitative image biomarkers. The results indicate that we could achieve 93% to 99% successful segmentation for these algorithms on this relatively large image database. The presented evaluation method may be scaled to much larger image databases.
Segmentation of the sternum in medical images is of clinical significance as it frequently serves as a stable reference to image registration and segmentation of other organs in the chest region. In this paper we present a fully automated algorithm to segment the sternum in low-dose chest CT images (LDCT). The proposed algorithm first locates an axial seed slice and then segments the sternum cross section on the seed slice by matching a rectangle model. Furthermore, it tracks and segments the complete sternum in the cranial and caudal direction respectively through sequential axial slices starting from the seed slice. The cross section on each axial slice is segmented using score functions that are designed to have local maxima at the boundaries of the sternum. Finally, the sternal angle is localized. The algorithm is designed to be specifically robust with respect to cartilage calcifications and to accommodate the high noise levels encountered with LDCT images. Segmentation of 351 cases from public datasets was evaluated visually with only 1 failing to produce a usable segmentation. 87.2% of the 351 images have good segmentation and 12.5% have acceptable segmentation. The sternal body segmentation and the localization of the sternal angle and the vertical extents of the sternum were also evaluated quantitatively for 25 good cases and 25 acceptable cases. The overall weighted mean DC of 0.897 and weighted mean distance error of 2.88 mm demonstrate that the algorithm achieves encouraging performance in both segmenting the sternal body and localizing the sternal angle.
The segmentation of whole breast serves as the first step towards automated breast lesion detection. It is also necessary for automatically assessing the breast density, which is considered to be an important risk factor for breast cancer. In this paper we present a fully automated algorithm to segment the whole breast in low-dose chest CT images (LDCT), which has been recommended as an annual lung cancer screening test. The automated whole breast segmentation and potential breast density readings as well as lesion detection in LDCT will provide useful information for women who have received LDCT screening, especially the ones who have not undergone mammographic screening, by providing them additional risk indicators for breast cancer with no additional radiation exposure. The two main challenges to be addressed are significant range of variations in terms of the shape and location of the breast in LDCT and the separation of pectoral muscles from the glandular tissues. The presented algorithm achieves robust whole breast segmentation using an anatomy directed rule-based method. The evaluation is performed on 20 LDCT scans by comparing the segmentation with ground truth manually annotated by a radiologist on one axial slice and two sagittal slices for each scan. The resulting average Dice coefficient is 0.880 with a standard deviation of 0.058, demonstrating that the automated segmentation algorithm achieves results consistent with manual annotations of a radiologist.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
INSTITUTIONAL Select your institution to access the SPIE Digital Library.
PERSONAL Sign in with your SPIE account to access your personal subscriptions or to use specific features such as save to my library, sign up for alerts, save searches, etc.