The in-orbit performance verification and calibration of the X-ray Mirror Assembly (XMA) on the XRISM satellite are ongoing. The optical performance of the XMA is being measured with bright point-like or bright small enough sources in orbit. This paper reports the preliminary results for the XMA of Resolve (Resolve- XMA). The in-orbit on-axis and off-axis (1.8′–9′ away from the aimpoint) Point Spread Function (PSF) of the Resolve-XMA were measured using 3C 273 and Cyg X-2, respectively. No significant changes were found in the PSF compared to on-ground results, indicating that the Resolve-XMA is functioning as expected (HPD ∼ 1.3′). For the Effective Area (EA) calibration, XRISM observed 3C 273 alongside other satellites. The Resolve spectrum of 3C 273 is well reproduced by an absorbed power law. While the best-fit photon index is consistent with that measured by NuSTAR, the flux is 5% higher than the NuSTAR measurement. In-orbit stray light observation was conducted with Crab at 60′ off from the aimpoint, and a signature of stray light on Resolve was detected. The observation of Resolve optical search has not yet been performed, and GX 3+1 has been proposed as the target.
The Advanced X-ray Imaging Satellite (AXIS), a concept recently submitted to NASA’s Astrophysics Probe Explorer competition, will offer low-background, arcsecond-resolution imaging in the 0.3–10 keV band across a 450-arcmin2 field of view, with an effective area at 1 keV of at least 4200 cm2. AXIS will bring X-ray astronomy back to the forefront of modern mainstream astrophysics, reaching equivalent depths in X-rays to many of the major facilities of the 2030’s (e.g., JWST, Roman, Rubin, ngVLA, LISA) to address the most important questions identified by the Astro2020 Decadal Survey. Here, we present an update on the status of AXIS.
The X-Ray Imaging and Spectroscopy Mission (XRISM) project at JAXA officially started in 2018. Following the development of onboard components, the proto-flight test was conducted from 2021 to 2023 at JAXA Tsukuba Space Center. The spacecraft was launched from JAXA Tanegashima Space Center on September 7, 2023 (JST), and onboard components, including the science instruments, were activated during the in-orbit commissioning phase. Following the previous report in 2020, we report the spacecraft ground tests, the launch operation, in-orbit operations, and the status and plan of initial and subsequent guest observations.
The Advanced X-ray Imaging Satellite (AXIS) is a Probe-class concept that will build on the legacy of the Chandra x-ray Observatory by providing low-background, arcsecond-resolution in the 0.3-10 keV band across a 450 arcminute2 field of view, with an order of magnitude improvement in sensitivity. AXIS utilizes breakthroughs in the construction of lightweight segmented x-ray optics using single-crystal silicon, and developments in the fabrication of large-format, small-pixel, high readout rate CCD detectors with good spectral resolution, allowing a robust and cost-effective design. Further, AXIS will be responsive to target-of-opportunity alerts and, with onboard transient detection, will be a powerful facility for studying the time-varying x-ray universe, following on from the legacy of the Neil Gehrels (Swift) x-ray observatory that revolutionized studies of the transient x-ray Universe. In this paper, we present an overview of AXIS, highlighting the prime science objectives driving the AXIS concept and how the observatory design will achieve these objectives.
The X-Ray Imaging and Spectroscopy Mission (XRISM) is the successor to the 2016 Hitomi mission that ended prematurely. Like Hitomi, the primary science goals are to examine astrophysical problems with precise highresolution X-ray spectroscopy. XRISM promises to discover new horizons in X-ray astronomy. XRISM carries a 6 x 6 pixelized X-ray micro-calorimeter on the focal plane of an X-ray mirror assembly and a co-aligned X-ray CCD camera that covers the same energy band over a large field of view. XRISM utilizes Hitomi heritage, but all designs were reviewed. The attitude and orbit control system were improved in hardware and software. The number of star sensors were increased from two to three to improve coverage and robustness in onboard attitude determination and to obtain a wider field of view sun sensor. The fault detection, isolation, and reconfiguration (FDIR) system was carefully examined and reconfigured. Together with a planned increase of ground support stations, the survivability of the spacecraft is significantly improved.
The XRISM X-ray observatory will fly two advanced instruments, the Resolve high-resolution spectrometer and the Xtend wide-field imager. These instruments, particularly Resolve, pose calibration challenges due to the unprecedented combination of spectral resolution, spectral coverage, and effective area, combined with a need to characterize the imaging fidelity of the full instrument system to realize the mission’s ambitious science goals. We present the status of the XRISM in-flight calibration plan, building on lessons from Hitomi and other X-ray missions. We present a discussion of targets and observing strategies to address the needed calibration measurements, with a focus on developing methodologies to plan a thorough and flexible calibration campaign and provide insight on calibration systematic error. We also discuss observations that exploit Resolve’s spectral
The ASTRO-H mission was designed and developed through an international collaboration of JAXA, NASA, ESA, and the CSA. It was successfully launched on February 17, 2016, and then named Hitomi. During the in-orbit verification phase, the on-board observational instruments functioned as expected. The intricate coolant and refrigeration systems for soft X-ray spectrometer (SXS, a quantum micro-calorimeter) and soft X-ray imager (SXI, an X-ray CCD) also functioned as expected. However, on March 26, 2016, operations were prematurely terminated by a series of abnormal events and mishaps triggered by the attitude control system. These errors led to a fatal event: the loss of the solar panels on the Hitomi mission. The X-ray Astronomy Recovery Mission (or, XARM) is proposed to regain the key scientific advances anticipated by the international collaboration behind Hitomi. XARM will recover this science in the shortest time possible by focusing on one of the main science goals of Hitomi,“Resolving astrophysical problems by precise high-resolution X-ray spectroscopy”.1 This decision was reached after evaluating the performance of the instruments aboard Hitomi and the mission’s initial scientific results, and considering the landscape of planned international X-ray astrophysics missions in 2020’s and 2030’s. Hitomi opened the door to high-resolution spectroscopy in the X-ray universe. It revealed a number of discrepancies between new observational results and prior theoretical predictions. Yet, the resolution pioneered by Hitomi is also the key to answering these and other fundamental questions. The high spectral resolution realized by XARM will not offer mere refinements; rather, it will enable qualitative leaps in astrophysics and plasma physics. XARM has therefore been given a broad scientific charge: “Revealing material circulation and energy transfer in cosmic plasmas and elucidating evolution of cosmic structures and objects”. To fulfill this charge, four categories of science objectives that were defined for Hitomi will also be pursued by XARM; these include (1) Structure formation of the Universe and evolution of clusters of galaxies; (2) Circulation history of baryonic matters in the Universe; (3) Transport and circulation of energy in the Universe; (4) New science with unprecedented high resolution X-ray spectroscopy. In order to achieve these scientific objectives, XARM will carry a 6 × 6 pixelized X-ray micro-calorimeter on the focal plane of an X-ray mirror assembly, and an aligned X-ray CCD camera covering the same energy band and a wider field of view. This paper introduces the science objectives, mission concept, and observing plan of XARM.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
INSTITUTIONAL Select your institution to access the SPIE Digital Library.
PERSONAL Sign in with your SPIE account to access your personal subscriptions or to use specific features such as save to my library, sign up for alerts, save searches, etc.