The advanced baseline imager (ABI) onboard Geostationary Operational Environmental Satellites-16 (GOES-16) provides high-quality visible and near-infrared (VNIR) imagery data. Radiometric performance of the GOES-16 ABI multiple VNIR bands (B1, B2, B3, B5, and B6) is evaluated over the Sonoran Desert by comparing measurements with Suomi National Polar-Orbiting Partnership (S-NPP) and NOAA-20 visible infrared imaging radiometer suite equivalent bands M3, M5, M7, M10, and M11, respectively. In order to minimize the uncertainties due to the difference in spectral response functions of similar bands from the different sensors, spectral band adjustment factor (SBAF) derived from Hyperion data over Sonoran Desert is used. The large viewing angle at the Sonoran Desert by ABI (56.34 deg) and a lack of comprehensive BRDF model at such viewing geometry are the main challenges for the comparison. Two schemes to address such challenges were developed. A data-derived (DD) method, based on confining the matched solar-zenith angle and view-zenith angle between ABI and VIIRS, interpolation in solar-zenithal and relative-azimuthal angles is developed to address this issue. It is shown that there is some residual bias for ABI B1 and its equivalent VIIRS M3 band, which is mainly due to unaccounted angular dependence of atmospheric scattering in this DD method. To address this issue, a radiative transfer modeling (RTM)-based method to account for atmospheric effects is developed to facilitate the comparison. The time series trending and mean bias of reflectance ratio between ABI and VIIRS measurements over the Sonoran Desert after SBAF and bidirectional reflectance distribution function corrections are derived to evaluate the radiometric performance of ABI with respect to net primary productivity and NOAA-20 VIIRS. The analysis shows that the radiometric biases of the five VNIR channels of GOES-16 ABI are all within 5% in comparison to the matched channels of NPP VIIRS after applying the RTM correction. The analysis also detects ∼6 % drop in the radiometric bias of GOES-16 ABI 0.64 μm channel after April 23, 2019, which can be traced to the implementation of a correction of the ABI B2 calibration coefficient around this date. Further, we evaluate the relative radiometric bias for the five VNIR channels between NPP and NOAA-20 VIIIRS using double difference method, and the comparison shows that NPP VIIRS has 2% to 3% higher bias than NOAA-20 VIIRS for these spectral bands.
The Advanced Baseline Imager (ABI) onboard GOES-16 provides high quality visible and near-infrared (VNIR) imagery data. In this paper, radiometric performance of the GOES-16 ABI multiple VNIR bands (B1, B2, B3, B5, and B6) are evaluated over the Sonoran Desert by comparing measurements with Suomi National Polar-Orbiting Partnership (SNPP) Visible Infrared Imaging Radiometer Suite (VIIRS) equivalent bands M3, M5, M7, M10, and M11 and Aqua MODIS (Moderate Resolution Imaging Spectroradiometer) equivalent bands b3, b1, b2, b6 and b7, respectively. Spectral Band Adjustment Factor (SBAF) derived from Hyperion data over Sonoran Desert is used. The large viewing angle at the Sonoran Desert by ABI (56.34º) and a lack of comprehensive BRDF model at such viewing geometry and angular dependence of atmospheric scattering are the main challenges for the comparison. To address this issue, a radiative transfer modeling-based (RTM) method to account for atmospheric effects is developed to facilitate the comparison. The time series trending and mean bias of reflectance ratio between ABI and VIIRS and MODIS measurements over the Sonoran Desert after SBAF and BRDF corrections are derived to evaluate the radiometric performance of ABI w.r.t. VIIRS and MODIS. The analysis shows that the radiometric biases of the first four VNIR channels of GOES-16 ABI are all within 6% in comparison to the matched channels of VIIRS or MODIS after applying the RTM correction. Only the reflectance consistency of the VIIRS M11 and MODIS b7 is ~0.09, which dues to the center wavelength difference and different H2O absorption effects. The analysis also detects ~6% drop in the radiometric bias of GOES-16 ABI 0.64 μm channel after April 23, 2019, which can be traced to the implementation of a correction of the ABI B2 calibration coefficient around this date.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
INSTITUTIONAL Select your institution to access the SPIE Digital Library.
PERSONAL Sign in with your SPIE account to access your personal subscriptions or to use specific features such as save to my library, sign up for alerts, save searches, etc.