Paper
23 August 2000 Design and reliability aspects of multilevel metal large-scale power line layouts in ULSI-ICs
Peter J. Jacob, Giovanni Nicoletti
Author Affiliations +
Abstract
Integration of both extremely small-dimensioned metal lines and large-dimensioned metal structures may cause reliability problems due to thermomechanical stress between the intermetal dielectric and the multi-level-metalization. The paper reports a case study and shows a problem solution approach: due to thermomechanical mismatch of aluminum and Si-oxide, metalization processing should not be used for both small and large structures. This may cause cracks and generate intermetallic shorts as a reliability problem.
© (2000) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Peter J. Jacob and Giovanni Nicoletti "Design and reliability aspects of multilevel metal large-scale power line layouts in ULSI-ICs", Proc. SPIE 4182, Process Control and Diagnostics, (23 August 2000); https://doi.org/10.1117/12.410074