25 June 2021 Simulation of laser-induced retinal thermal injuries for non-uniform irradiance profiles and the applicability of the laser safety standard
Author Affiliations +
Abstract

Significance: A validated biophysical computer model simulating retinal thermal damage thresholds is used to investigate elongated retinal images. The International Commission on Non-Ionizing Radiation Protection Guideline and the laser safety standard IEC 60825-1:2014 include a method for averaging non-uniform extended sources, however, there are no studies that have examined the applicability in detail. Our study represents a method that can also support future research in the field of eye safety.

Aim: As there is currently no experimental data available for non-uniform irradiance profiles, the calculation procedure given in the laser safety standard is derived from symmetric retinal images. We aim to verify this calculation procedure for such profiles on the retina in the thermal hazard regime.

Approach: A three-dimensional computer model, which solves the heat transfer equation and the Arrhenius equation describing the denaturation of the proteins in the retina, is used to simulate the threshold values for the retinal thermal injury. Three different non-uniform irradiance profiles, elliptical Gaussian, elliptical top-hat, and rectangular top-hat distributions, are investigated for a wavelength of 530 nm. The profiles are varied in their sizes and simulated for different single-pulse durations. By applying the laser safety standard, the maximum allowed energies are calculated and divided by the corresponding threshold values to obtain the reduction factor (RF) which is a crucial parameter.

Results: Due to the thermal behavior in the retinal tissues, the Gaussian irradiance profiles yield larger threshold values than both top-hat profiles. Furthermore, the ratio between the threshold values and the maximum allowed energies are found to be the lowest for the Gaussian profiles.

Conclusion: The simulated retinal thermal injury thresholds for the three investigated non-uniform irradiance profiles show larger RFs than the minimum RF found for symmetric profiles. This supports the applicability of the evaluation scheme of the laser safety standard for non-uniform retinal images.

© 2021 Society of Photo-Optical Instrumentation Engineers (SPIE) 0091-3286/2021/$28.00 © 2021 SPIE
Sebastian Kotzur, Siegfried Wahl, and Annette Frederiksen "Simulation of laser-induced retinal thermal injuries for non-uniform irradiance profiles and the applicability of the laser safety standard," Optical Engineering 60(6), 066115 (25 June 2021). https://doi.org/10.1117/1.OE.60.6.066115
Received: 8 January 2021; Accepted: 10 June 2021; Published: 25 June 2021
Lens.org Logo
CITATIONS
Cited by 2 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Laser safety

Injuries

Standards development

Retina

Computer simulations

Optical simulations

Eye

RELATED CONTENT

Use of laser pointers and the related hazards
Proceedings of SPIE (July 14 1998)
Overview of the range of mechanisms
Proceedings of SPIE (March 03 2000)
Retinal Thermal Injury
Proceedings of SPIE (October 07 1980)
Laser Safety In Manufacturing
Proceedings of SPIE (February 28 1978)

Back to Top