Paper
22 March 2016 Evaluation of Tizian overlays by means of a swept source optical coherence tomography system
Author Affiliations +
Proceedings Volume 9670, Sixth International Conference on Lasers in Medicine; 96700X (2016) https://doi.org/10.1117/12.2191905
Event: Sixth International Conference on Lasers in Medicine, 2015, Bucharest, Romania
Abstract
The teeth affected by pathologic attrition can be restored by a minimally invasive approach, using Tizian overlays. In this study we prove the advantages of a fast swept source (SS) OCT system in the evaluation of Tizian overlays placed in an environment characterized by high occlusal forces. 12 maxillary first premolars were extracted and prepared for overlays. The Tizian overlays were subjected to 3000 alternating cycles of thermo-cycling (from -10°C to +50°C) and to mechanical occlusal overloads (at 800 N). A fast SS OCT system was used to evaluate the Tizian overlays before and after the mechanical and thermal straining. The SS (Axsun Technologies, Billerica, MA) has a central wavelength of 1060 nm, sweeping range of 106 nm (quoted at 10 dB) and a 100 kHz line rate. The depth resolution of the system, measured experimentally in air was 10 μm. The imaging system used for this study offers high spatial resolutions in both directions, transversal and longitudinal of around 10 μm, a high sensitivity, and it is also able to acquire entire tridimensional (3D)/volume reconstructions as fast as 2.5 s. Once the full dataset was acquired, rendered high resolutions en-face projections could be produced. Using them, the overlay (i.e., cement) abutment tooth interfaces were remarked both on B-scans/two-dimensional (2D) sections and in the 3D reconstructions. Using the system several open interfaces were possible to detect. The fast SS OCT system thus proves useful in the evaluation of zirconia reinforced composite overlays, placed in an environment characterized by high occlusal forces.
© (2016) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Corina Marcauteanu, Cosmin Sinescu, Meda Lavinia Negrutiu, Eniko Tunde Stoica, Florin Topala, Virgil Florin Duma, Adrian Bradu, and Adrian Gh. Podoleanu "Evaluation of Tizian overlays by means of a swept source optical coherence tomography system ", Proc. SPIE 9670, Sixth International Conference on Lasers in Medicine, 96700X (22 March 2016); https://doi.org/10.1117/12.2191905
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Optical coherence tomography

Teeth

Interfaces

Composites

Imaging systems

Spatial resolution

Zirconium dioxide

Back to Top