Paper
25 July 2014 Cross strip anode readouts for large format, photon counting microchannel plate detectors: developing flight qualified prototypes of the detector and electronics
John Vallerga, Rick Raffanti, Michael Cooney, Harley Cumming, Gary Varner, Andrej Seljak
Author Affiliations +
Abstract
Photon counting microchannel plate (MCP) imagers have been the detector of choice for most UV astronomical missions over the last two decades (e.g. EUVE, FUSE, COS on Hubble etc.). Over this duration, improvements in the MCP laboratory readout technology have resulted in better spatial resolution (x10), temporal resolution (x1000) and output event rate (x100), all the while operating at lower gain (x 10) resulting in lower high voltage requirements and longer MCP lifetimes. One such technology is the parallel cross strip (PXS) readout. Laboratory versions of PXS electronics have demonstrated < 20 μm FWHM spatial resolution, count rates on the order of 2 MHz, and temporal resolution of ~ 1ns. In 2012 our group at U.C. Berkeley, along with our partners at the U. Hawaii, received a Strategic Astrophysics Technology grant to raise the TRL of the PXS detector and electronics from 4 to 6 by replacing most of the high powered electronics with application specific integrated circuits (ASICs) which will lower the power, mass and volume requirements of the PXS detector. We were also tasked to design and fabricate a "standard" 50mm square active area MCP detector incorporating these electronics that can be environmentally qualified for flight (temperature, vacuum, vibration). The first ASICs designed for this program have been fabricated and are undergoing testing. We present the latest progress on these ASIC designs and performance and show imaging results from the new 50 x 50 mm XS detector.
© (2014) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
John Vallerga, Rick Raffanti, Michael Cooney, Harley Cumming, Gary Varner, and Andrej Seljak "Cross strip anode readouts for large format, photon counting microchannel plate detectors: developing flight qualified prototypes of the detector and electronics", Proc. SPIE 9144, Space Telescopes and Instrumentation 2014: Ultraviolet to Gamma Ray, 91443J (25 July 2014); https://doi.org/10.1117/12.2058412
Lens.org Logo
CITATIONS
Cited by 12 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Microchannel plates

Sensors

Amplifiers

Electronics

Spatial resolution

Field programmable gate arrays

Analog electronics

Back to Top