3 March 2014 Modeling the shape of cylindrically focused transducers in three-dimensional optoacoustic tomography
Daniel Queirós, Xosé Luís Déan-Ben, Andreas Buehler, Daniel Razansky, Amir Rosenthal, Vasilis Ntziachristos
Author Affiliations +
Abstract
Image reconstruction in optoacoustics usually employs algorithms that assume ultrasonic transducers to be confined to points. This assumption deviates strongly from realistic detectors and is the cause of severe artifacts in the reconstructions. We propose two model-based image reconstruction algorithms that account for the shape of cylindrically focused ultrasonic transducers in three-dimensional optoacoustic tomography. The algorithms have been proved favorable in simulations and experiments.
© (2014) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Daniel Queirós, Xosé Luís Déan-Ben, Andreas Buehler, Daniel Razansky, Amir Rosenthal, and Vasilis Ntziachristos "Modeling the shape of cylindrically focused transducers in three-dimensional optoacoustic tomography", Proc. SPIE 8943, Photons Plus Ultrasound: Imaging and Sensing 2014, 89432F (3 March 2014); https://doi.org/10.1117/12.2036575