29 March 2013 Comparative studies of collimator performance in DaTscan (Ioflupane I-123) striatal SPECT
Andrzej Krol, Mary A. McGrath, Brian T. Carey, David H. Feiglin
Author Affiliations +
Abstract
Purpose: To determine optimal collimator and gamma camera combination for Ioflupane I-123 (DaTscan) striatal SPECT. Methods: Anthropomorphic basal ganglia phantom was used. The striatal chambers (caudate and putamen chambers) and the large chamber simulating nonspecific background activity in the remainder of the brain were filled with I-123 with the specific activity ratio 7.7. SPECT data were acquired using triple-head gamma camera (THGC) with fan-beam low-energy ultra high-resolution (LEUR) collimators, with dual-head gamma camera (DHGC) with parallel-beam lowenergy high-resolution (LEHR) collimators and medium-energy general-purpose (MEGP) collimators. Data were acquired at 159 keV with a 20% window, with I-123 and Tc-99m flood table for THGC and DHGC, respectively. The images were reconstructed using the OSEM algorithm with resolution modeling and uniform attenuation correction, and Butterworth postfilter, 5th order and 0.64, 0.78 and 1.0 Ny for LEUR, LEHR, and MEGP, respectively. The filter parameters were chosen to optimize the balance between image noise and spatial resolution. Results: The best image quality in terms of spatial resolution and contrast was obtained with fan-beam LEUR/THGC. The MEGP/DHBC produced images with better contrast-to-noise ratio than LEHR/DHGC. The measured ratio of mean activity in striatal chambers to the remainder of the brain was comparable for all three collimator/camera combinations. Conclusions: Based on phantom DaTscan striatal SPECT, the THGC with fan-beam LEUR collimators is preferable. If DHGC is used MEGP collimators provide better image quality, as compared to LEHR. More studies including patient studies are needed to confirm best collimator/camera combination.
© (2013) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Andrzej Krol, Mary A. McGrath, Brian T. Carey, and David H. Feiglin "Comparative studies of collimator performance in DaTscan (Ioflupane I-123) striatal SPECT", Proc. SPIE 8672, Medical Imaging 2013: Biomedical Applications in Molecular, Structural, and Functional Imaging, 867204 (29 March 2013); https://doi.org/10.1117/12.2007027
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Collimators

Cameras

Single photon emission computed tomography

Brain

Image quality

Data acquisition

Spatial resolution

Back to Top