17 September 2012 The use of CCDs and EM-CCDs for future soft x-ray spectrometers
Author Affiliations +
Abstract
CCDs have been used on several successful X-ray space missions including high resolution soft X-ray spectrometers, such as the Reflection Grating Spectrometer on XMM-Newton1 and the LETG and HETG on Chandra2. These instruments had a resolving power of ( E / Δ E) ~300; however, with new technology this can be improved allowing resolution to the thermal limit. In the soft X-ray band (200 eV to 10 keV) a resolution of around 3000 is required resolve all of the possible absorption and emission features. Through the development of instruments for the OP-XGS on IXO3 and the WHIMEx explorer mission4 it has been shown that an instrument capable of this resolution on a spacecraft is possible. CCDs are the ideal detector for use in detection of X-rays at this energy as they provide positional information allowing a high level of spatial resolution and their inherent energy resolution allowing diffracted orders to be separated. This paper will investigate the use of CCDs and possible use of EM-CCDs in soft X-ray spectroscopy. The multiplication of signal in the charge domain can increase the detectability of low energy photons, improving the Signal-to-Noise Ratio. Multiplication gain has been shown to degrade the resolution of a device as described by the Modified Fano Factor5, so this has to be taken into account in instrument design when overlapping spectral orders are needed to achieved the necessary resolution. The use of optical filters on the CCDs and their effect on quantum efficiency at soft X-ray energies is discussed together with possible improvements to existing technology.
© (2012) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
James H. Tutt, Andrew D. Holland, Neil J. Murray, David J. Hall, James Endicott, and Randall L McEntaffer "The use of CCDs and EM-CCDs for future soft x-ray spectrometers", Proc. SPIE 8443, Space Telescopes and Instrumentation 2012: Ultraviolet to Gamma Ray, 84430K (17 September 2012); https://doi.org/10.1117/12.925138
Lens.org Logo
CITATIONS
Cited by 2 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
X-rays

Charge-coupled devices

Spectral resolution

Spectrometers

Sensors

Photons

X-ray detectors

RELATED CONTENT

Evaluation of a gas-microstrip dual-energy system
Proceedings of SPIE (May 02 1997)
The use of EM CCDs on high resolution soft x...
Proceedings of SPIE (September 13 2011)
High Resolution X-Ray-Tv-Sensors
Proceedings of SPIE (February 01 1985)
Multilayer x-ray-sensitive CCDs
Proceedings of SPIE (April 30 2002)

Back to Top