3 March 2012 Resolution enhancement of computed radiography images using two orthogonal tilts
Steven I. Pollmann, Chris J. D. Norley, Xunhua Yuan, David W. Holdsworth
Author Affiliations +
Abstract
Limitations to the spatial resolution of current digital x-ray systems are bounded by the physical characteristics of the xray detector. However, the need to image smaller structures provides motivation to develop high-resolution x-ray detector systems for use with computed radiographic, and tomographic x-ray systems. We report the implementation of a tilted detector technique (TDT) to attain near isotropic resolution enhancement by combining two orthogonal image views, acquired with existing detector hardware tilted at a fixed angle. Images were acquired using a ceiling-mounted x-ray unit (Proteus XR/a, GE Medical Systems, 50kVp, 250mAs). Images were digitized using a Fujifilm Capsula X CR system, from a 35×43cm detector cassette placed on an angulated stand, featuring a 3520×4280 image matrix with an in-plane pixel spacing of 0.1mm. Three images were acquired: two for use with our TDT; and one for comparison, with no detector tilt. Performance was determined by using two line-pair phantoms (Models 07-521 and 07-533, Nuclear Associates) placed orthogonally to each other in the field of view. Custom software corrected for perspective distortion, co-registered and combined the tilted-detector images into a single higher-resolution image. Following unwarping and co-registration, the limiting spatial resolution of an image obtained via the weighted combination of the two orthogonal views (8 lp/mm) is found to be superior to that of a single view acquired with no detector tilt (5 lp/mm). This novel technique shows significant improvement in the spatial resolution of x-ray image acquisitions, using existing x-ray components and detector hardware.
© (2012) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Steven I. Pollmann, Chris J. D. Norley, Xunhua Yuan, and David W. Holdsworth "Resolution enhancement of computed radiography images using two orthogonal tilts", Proc. SPIE 8313, Medical Imaging 2012: Physics of Medical Imaging, 831313 (3 March 2012); https://doi.org/10.1117/12.913321
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Sensors

Image resolution

Resolution enhancement technologies

X-ray detectors

X-rays

Spatial resolution

X-ray imaging

RELATED CONTENT

A study of EM failure in a micro scale Pb...
Proceedings of SPIE (September 11 2014)
X-Ray tomography with micrometer spatial resolution
Proceedings of SPIE (October 24 1997)

Back to Top