27 May 2011 Calibration routine for in-process roundness measurements of steel rings during heat treatment
Author Affiliations +
Abstract
This paper reports on the calibration routine developed for an absolute measurement of the mean radius and the ovality of a ring. By means of six laser triangulation sensors, the measurements are performed in-process in a furnace during heat treatment. The lack of precise information about the exact position and direction of the sensors and the minimal accessibility of the ring in the furnace is challenging and leads to a complex calibration routine. The calibration includes the application of gauge rings with different diameters. The developed routine is described and calibrated measurement results are compared with coordinate measurement machine (cmm) data. Concerning the ring radius (~ 72.5 mm), the comparison exhibits a deviation to the cmm data of less than 35 μm.
© (2011) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
H. Gafsi and G. Goch "Calibration routine for in-process roundness measurements of steel rings during heat treatment", Proc. SPIE 8082, Optical Measurement Systems for Industrial Inspection VII, 808231 (27 May 2011); https://doi.org/10.1117/12.889515