Paper
13 May 2011 An implementation for the detection and analysis of negative peaks in an applied current signal across a silicon nanopore
Joseph A. Billo, Waseem Asghar, Samir M. Iqbal
Author Affiliations +
Abstract
Translocation of DNA through a silicon nanopore with an applied voltage bias causes the ionic current signal to spike sharply downward as molecules block the flow of ions through the pore. Proper processing of the sampled signal is paramount in obtaining accurate translocation kinetics from the negative peaks, but manual analysis is time-consuming. Here, an algorithm is reported that automates the process. It imports the signal from a tab-delimited text file, automatically zero-baselines, filters noise, detects negative peaks, and estimates each peak's start and end time. The imported signal is processed using a zero-overlap sampling window. Peaks are detected by comparison of the window's standard deviation to a threshold standard deviation in addition to a comparison against a peak magnitude threshold. Zero-baselining and noise removal is accomplished through calculation of the mean of non-peak window values. The start and end times of a peak are approximated by checking where the signal becomes positive on either side of the peak. The program then stores the magnitude, sample number, approximate start time, and approximate end time of each peak in a matrix. All these tasks are automatically done by the program, requiring only the following initial input from the user: window size, file path to sampled signal data file, standard deviation threshold, peak magnitude threshold, and sampling frequency of the sampled signal. Trials with signals from an 11-micron pore sampled at 100 kHz for 30 seconds yielded a high rate of successful peak detection with a magnitude threshold of 600, a standard deviation threshold of 1.25, and a window size of 100.
© (2011) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Joseph A. Billo, Waseem Asghar, and Samir M. Iqbal "An implementation for the detection and analysis of negative peaks in an applied current signal across a silicon nanopore", Proc. SPIE 8031, Micro- and Nanotechnology Sensors, Systems, and Applications III, 80312T (13 May 2011); https://doi.org/10.1117/12.884088
Lens.org Logo
CITATIONS
Cited by 5 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Signal detection

Silicon

Signal processing

Interference (communication)

Ions

Analytical research

Proteins

Back to Top