Paper
5 October 2009 Fiber optic methane monitor based TDLAS and its application in VAM Oxidiser system
Yubin Wei, Yanfang Li, Yanjie Zhao, Tongyu Liu
Author Affiliations +
Proceedings Volume 7503, 20th International Conference on Optical Fibre Sensors; 75034N (2009) https://doi.org/10.1117/12.836176
Event: 20th International Conference on Optical Fibre Sensors, 2009, Edinburgh, United Kingdom
Abstract
Fiber optic methane monitor based tunable diode laser absorption spectroscope technology (TDLAS) is demonstrated, which is developed for remotely monitoring the concentration of Methane gas at multiple locations. A DFB LD light source of 1665nm is the key unit in the system.A microprocessor is used to control the driver of DFB LD and Acquire data.To realize high precision measure of CH4,we use a reference cell. The instrument achived long time precision of 0.05%(for 0~4% full scale range) and 0.5%(for 0~100% full scale range).The instruments has been used to monitor the mathane of a VAM Oxidiser unit in methane power generation in a long time .The results of measurement are shown and discussed in this paper.
© (2009) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Yubin Wei, Yanfang Li, Yanjie Zhao, and Tongyu Liu "Fiber optic methane monitor based TDLAS and its application in VAM Oxidiser system", Proc. SPIE 7503, 20th International Conference on Optical Fibre Sensors, 75034N (5 October 2009); https://doi.org/10.1117/12.836176
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Methane

Fiber optics

Sensors

Fiber optics sensors

Gas sensors

Absorption

Light sources

RELATED CONTENT


Back to Top