27 March 2008 Optimized acquisition scheme for multi-projection correlation imaging of breast cancer
Author Affiliations +
Abstract
We are reporting the optimized acquisition scheme of multi-projection breast Correlation Imaging (CI) technique, which was pioneered in our lab at Duke University. CI is similar to tomosynthesis in its image acquisition scheme. However, instead of analyzing the reconstructed images, the projection images are directly analyzed for pathology. Earlier, we presented an optimized data acquisition scheme for CI using mathematical observer model. In this article, we are presenting a Computer Aided Detection (CADe)-based optimization methodology. Towards that end, images from 106 subjects recruited for an ongoing clinical trial for tomosynthesis were employed. For each patient, 25 angular projections of each breast were acquired. Projection images were supplemented with a simulated 3 mm 3D lesion. Each projection was first processed by a traditional CADe algorithm at high sensitivity, followed by a reduction of false positives by combining geometrical correlation information available from the multiple images. Performance of the CI system was determined in terms of free-response receiver operating characteristics (FROC) curves and the area under ROC curves. For optimization, the components of acquisition such as the number of projections, and their angular span were systematically changed to investigate which one of the many possible combinations maximized the sensitivity and specificity. Results indicated that the performance of the CI system may be maximized with 7-11 projections spanning an angular arc of 44.8°, confirming our earlier findings using observer models. These results indicate that an optimized CI system may potentially be an important diagnostic tool for improved breast cancer detection.
© (2008) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Amarpreet S. Chawla, Ehsan Samei, Robert S. Saunders, Joseph Y. Lo, and Swatee Singh "Optimized acquisition scheme for multi-projection correlation imaging of breast cancer", Proc. SPIE 6915, Medical Imaging 2008: Computer-Aided Diagnosis, 691528 (27 March 2008); https://doi.org/10.1117/12.773174
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Computer aided diagnosis and therapy

Image processing

Imaging systems

Diagnostics

Image segmentation

Breast

Mammography

Back to Top