Abstract
Laser Target Alignment Sensor (LTAS) focus high energy laser beams on the sub-centimeter size fusion targets at the precise location and adjusts the final focus lenses to set the spots size in Initial Control Fusion (ICF) experiment. The operational requirements of the ICF system place tight constraints upon the precision of the LTAS. Therefore, a calibration system which can adjust conjugation distance of the LTAS, compensate the location of the beam spots, and calculate the axis and magnification of the objectives is designed. The system is composed of a long focal-length telemicroscope, a high resolution CCD, a NC dividing head, an X-Y linear stage, a multidimensional target positioner and two simulated laser beam generators. Feedbacks based on the LTAS images of the target and laser points are used to null offsets of the LTAS on conjugation distance. The methods of objective and CCD parameter calibration are presented. Experiments for the positioning accuracy test show that after calibration, the repeatability error of the LTAS for the target center location is better than ±0.7&mgr;m. The system can realize accurate calibration of the LTAS before putting it into target chamber, which will improve the precision of ICF experiments effectively.
© (2007) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Lijun Bao, Zhuo Zhang, Guodong Liu, Bingguo Liu, and Zhaobang Pu "ICF laser target alignment sensor calibration system", Proc. SPIE 6595, Fundamental Problems of Optoelectronics and Microelectronics III, 65951K (5 March 2007); https://doi.org/10.1117/12.725805
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Calibration

Charge-coupled devices

Mirrors

CCD cameras

Objectives

Sensor calibration

Sensors

RELATED CONTENT

Performances of a CCD camera from 1 to 1100...
Proceedings of SPIE (September 25 1997)
A second optic head for the ELETTRA long trace profiler
Proceedings of SPIE (September 16 2005)
Use of x ray CCDs in the calibration of the...
Proceedings of SPIE (October 31 1996)
EPIC pn CCD camera onboard XMM Newton an update...
Proceedings of SPIE (August 18 2005)
Data processing in luminance distribution measurements
Proceedings of SPIE (October 11 2005)

Back to Top