Paper
7 May 2007 Optimization of the tomographic scanning (TOSCA) imager
Author Affiliations +
Abstract
The tomographic scanning (TOSCA) imager was invented by the author in 2003. Initially, the system was based on reconstructing an image from the signal of a simple single pixel, conical scan FM-reticle sensor using tomographic techniques. Although the system has been used for several decades for real-time tracking purposes, the imaging properties of the single pixel conical scan reticle system was left undiscovered until recently, although multi-target discrimination was demonstrated with multi-spectral versions of the system. The initial system presented by the author demonstrated the ability to discriminate between multiple spots in the field of view in a fairly simple scenario. Advances have been made in both theory and technology, mainly with the introduction of the nutating circular aperture in the scanning optics, and the use of Fourier transform ramp filters during reconstruction, and TOSCA is in principle found to be a perfect imaging system, only limited by practical aspects such as the number of angular scans, the spatial sampling, noise and vibration. The simplicity of the hardware, together with the rapid advances in high performance, low cost computing means the system has a potential for low-cost applications such as in expendable multi-spectral thermal imagers. This paper will present the current state of the technology, including improvements in algorithms and reticle shapes, and look at artefacts found in various images due to different geometries, as well as ways to handle these artefacts. Several noise generating processes and their effects will be presented and illustrated with results from digital simulations. Requirements for image processing in terms of computing power are investigated, together with the potential for parallelization.
© (2007) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Harald Hovland "Optimization of the tomographic scanning (TOSCA) imager", Proc. SPIE 6569, Acquisition, Tracking, Pointing, and Laser Systems Technologies XXI, 65690I (7 May 2007); https://doi.org/10.1117/12.719501
Lens.org Logo
CITATIONS
Cited by 2 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Reticles

Imaging systems

Tomography

Fourier transforms

Sensors

Spatial resolution

Missiles

RELATED CONTENT

Spin scan tomographic imager
Proceedings of SPIE (May 26 2015)
Rotary infrared tomography system design
Proceedings of SPIE (November 07 2018)
Tomographic scanning imaging seeker
Proceedings of SPIE (July 27 2004)
Specialized tomographic scanning imaging seeker
Proceedings of SPIE (May 20 2005)
A micro-CT system for small-animal imaging
Proceedings of SPIE (December 08 2003)

Back to Top