This study evaluated the potential clinical utility of a high-performance (3 Mega-pixel) color display compared with two monochrome displays--one of comparable luminance (250 cd/m2) and one of higher luminance (450 cd/m2). Six radiologists viewed 50 DR chest images, half with nodules and half without, once on each display. Eye position was recorded on a subset of images. There was no statistically significant difference in ROC Az performance as a function of monitor (F = 1.176, p = 0.3127), although there was a clear trend towards the monochrome 450 cd/m2 monitor being better than the monochrome 250 cd/m2 monitor, which was better than the color monitor. In terms of total viewing time, there were no statistically significant differences between the three monitors (F = 1.478, p = 0.2298). The dwell times associated with true and false positive decisions were shortest for the high luminance monochrome display, longer for the low luminance monochrome, and longest for the low luminance color display. Dwells for the false negative decisions were longest for the high luminance monochrome display, shorter for the low luminance monochrome, and shortest for the low luminance color display. The true negative dwells were not significantly different. The study suggest high luminance displays may have an advantage in terms of diagnostic accuracy and visual search efficiency for detecting nodules in chest images compared to both monochrome and color lower luminance displays, although these differences may have little clinical impact because they are relatively small.
© (2007) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Elizabeth A. Krupinski, Hans Roehrig, Jiahua Fan, and Takahiro Yoneda "High luminance monochrome vs low luminance monochrome and color softcopy displays: observer performance and visual search efficiency", Proc. SPIE 6515, Medical Imaging 2007: Image Perception, Observer Performance, and Technology Assessment, 65150R (20 March 2007); https://doi.org/10.1117/12.706298
Lens.org Logo
CITATIONS
Cited by 6 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
LCDs

Visualization

Chest

Diagnostics

Eye

Radiology

CRTs

Back to Top