Paper
19 March 2007 The Juggler algorithm: a hybrid deformable image registration algorithm for adaptive radiotherapy
Author Affiliations +
Abstract
Fast deformable registration can potentially facilitate the clinical implementation of adaptive radiation therapy (ART), which allows for daily organ deformations not accounted for in radiotherapy treatment planning, which typically utilizes a static organ model, to be incorporated into the fractionated treatment. Existing deformable registration algorithms typically utilize a specific diffusion model, and require a large number of iterations to achieve convergence. This limits the online applications of deformable image registration for clinical radiotherapy, such as daily patient setup variations involving organ deformation, where high registration precision is required. We propose a hybrid algorithm, the "Juggler", based on a multi-diffusion model to achieve fast convergence. The Juggler achieves fast convergence by applying two different diffusion models: i) one being optimized quickly for matching high gradient features, i.e. bony anatomies; and ii) the other being optimized for further matching low gradient features, i.e. soft tissue. The regulation of these 2 competing criteria is achieved using a threshold of a similarity measure, such as cross correlation or mutual information. A multi-resolution scheme was applied for faster convergence involving large deformations. Comparisons of the Juggler algorithm were carried out with demons method, accelerated demons method, and free-form deformable registration using 4D CT lung imaging from 5 patients. Based on comparisons of difference images and similarity measure computations, the Juggler produced a superior registration result. It achieved the desired convergence within 30 iterations, and typically required <90sec to register two 3D image sets of size 256×256×40 using a 3.2 GHz PC. This hybrid registration strategy successfully incorporates the benefits of different diffusion models into a single unified model.
© (2007) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Junyi Xia, Yunmei Chen, and Sanjiv S. Samant "The Juggler algorithm: a hybrid deformable image registration algorithm for adaptive radiotherapy", Proc. SPIE 6510, Medical Imaging 2007: Physics of Medical Imaging, 65105J (19 March 2007); https://doi.org/10.1117/12.713693
Lens.org Logo
CITATIONS
Cited by 4 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Image registration

Radiotherapy

Detection and tracking algorithms

Diffusion

3D modeling

4D CT imaging

Computed tomography

Back to Top