Paper
17 March 2006 Human efficiency for detecting Gaussian signals in non-Gaussian distributed lumpy backgrounds using different display characteristics and scaling methods
Author Affiliations +
Abstract
A psychophysical study to measure human efficiency relative to the ideal observer for detecting a Gaussian signal at a known location in a non-Gaussian distributed lumpy background was conducted previously by the author. The study found that human efficiency was less than 2.2% while the ideal observer achieved 0.95 in terms of the area under the receiver operating characteristic curve. In this work, a psychophysical study was conducted with a number of changes that substantially improve upon the previous study design. First, a DICOM-calibrated monitor was used in this study for human-observer performance measurements, whereas an uncalibrated LCD monitor was used in the prior study. Second, two scaling methods to display image values were employed to see how scaling affects human performance for the same task. Third, a random order of image pairs was chosen for each observer to reduce any correlations in human performance that is likely caused by the fixed ordering of the image pairs in the prior study. Human efficiency relative to the ideal observer was found to be less than 3.8$% at the same performance level of the ideal observer as above. Our variance analysis indicates that neither scaling nor display made a significant difference in human performance on the tasks in the two studies. That is, we cannot say that either of these factors caused low human efficiency in these studies. Therefore, we conclude that using highly non-Gaussian distributed lumpy backgrounds in the tasks may have been the major source of low human efficiency.
© (2006) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Subok Park, Brandon Gallas, Aldo Badano, Nicholas Petrick, and Kyle Myers "Human efficiency for detecting Gaussian signals in non-Gaussian distributed lumpy backgrounds using different display characteristics and scaling methods", Proc. SPIE 6146, Medical Imaging 2006: Image Perception, Observer Performance, and Technology Assessment, 61460Q (17 March 2006); https://doi.org/10.1117/12.653902
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Signal detection

Error analysis

LCDs

Medical imaging

Imaging systems

Statistical analysis

Image processing

Back to Top