Paper
21 October 2005 SWIR to LWIR HgCdTe detectors and FPAs for remote sensing applications
A. I. D'Souza, M. G. Stapelbroek, L. Dawson, P. Ely, C. Yoneyama, J. Reekstin, H.-D. Shih, M. Skokan, T. Teherani, J. Robinson
Author Affiliations +
Abstract
Remote sensing programs require detectors with a variety of wavelengths. One example of remote sensing applications is the GOES-ABI program that requires linear arrays of detectors with cutoff wavelengths ranging from the visible to the VLWIR (λc ~ 15 μm). In order to target the variety of remote sensing applications, an internal task was conducted to develop detectors and linear arrays operating under nominal remote sensing applications. SWIR [λc(295 K) ~ 2.5 μm] test detectors have been measured as a function of temperature between 170 K and 295 K. At 200 K the RoA values are in the 106 ohm-cm2 range. MWIR [λc(60 K) = 5.3 μm] and LWIR [λc(60 K) = 10.5 μm] HgCdTe detectors in a 320 x 6 array format have also been measured at 60 K. Within the arrays, the detector size is 40 μm x 50 μm. The MWIR detector array has a mean quantum efficiency of 89.2 % with a standard deviation to mean ratio, σ/μ = 1.51 %. The integration time for the focal plane array (FPA) measurements is 1.76 ms with a frame rate of 557.7 Hz. Operability values exceeding 99.5 % have been obtained. In addition, test diodes at the edge of the array that did not go through a read out integrated circuit (ROIC) were also measured and had quantum efficiency ~ 86 % that agreed well with the ~ 87 % quantum efficiency measured for detectors in the array that were located near the test detectors. The LWIR arrays, measured at 60K also had high operability with only ~ 3 % of the detectors having out of family response. Using best detector select (BDS) feature in the read out integrated circuit (ROIC), a feature that picks out the best detector in every row of six detectors, a 320 x 1 array with 100 % operability is obtained. For the 320 x1 array constituted using the BDS feature, a 100 % operable LWIR array with average NEI value of 1.94x1011 ph/cm2/s at a flux of 7.0x1014 ph/cm2/s has been demonstrated.
© (2005) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
A. I. D'Souza, M. G. Stapelbroek, L. Dawson, P. Ely, C. Yoneyama, J. Reekstin, H.-D. Shih, M. Skokan, T. Teherani, and J. Robinson "SWIR to LWIR HgCdTe detectors and FPAs for remote sensing applications", Proc. SPIE 5978, Sensors, Systems, and Next-Generation Satellites IX, 597818 (21 October 2005); https://doi.org/10.1117/12.627752
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Sensors

Long wavelength infrared

Quantum efficiency

Readout integrated circuits

Remote sensing

Diodes

Mercury cadmium telluride

RELATED CONTENT

Large format high SNR SWIR HgCdTe Si FPA with multiple...
Proceedings of SPIE (April 28 2017)
Advanced MCT technologies in France
Proceedings of SPIE (May 14 2007)
SWIR to LWIR HDVIP HgCdTe detector array performance
Proceedings of SPIE (May 18 2006)
2K X 2K molecular beam epitaxy HgCdTe detectors for the...
Proceedings of SPIE (September 29 2004)
State-of-the-art HgCdTe infrared devices
Proceedings of SPIE (April 13 2000)

Back to Top