Paper
21 September 2005 Enhanced K-edge plasma angiography achieved with tungsten Kα rays utilizing gadolinium-based contrast media
Eiichi Sato, Yasuomi Hayasi, Rudolf Germer, Koji Kimura, Etsuro Tanaka, Hidezo Mori, Toshiaki Kawai, Takashi Inoue, Akira Ogawa, Shigehiro Sato, Kazuyoshi Takayama, Hideaki Ido
Author Affiliations +
Abstract
The tungsten plasma flash x-ray generator is useful in order to perform high-speed enhanced K-edge angiography using cone beams because Kα rays from the tungsten target are absorbed effectively by gadolinium-based contrast media. In the flash x-ray generator, a 150 nF condenser is charged up to 80 kV by a power supply, and flash x-rays are produced by the discharging. The x-ray tube is a demountable diode, and the turbomolecular pump evacuates air from the tube with a pressure of approximately 1 mPa. Since the electric circuit of the high-voltage pulse generator employs a cable transmission line, the high-voltage pulse generator produces twice the potential of the condenser charging voltage. At a charging voltage of 80 kV, the estimated maximum tube voltage and current were approximately 160 kV and 40 kA, respectively. When the charging voltage was increased, the characteristic x-ray intensities of tungsten Kα lines increased. Using an ytterbium oxide filter, the Kα lines were clean, and hardly any Kβ lines and bremsstrahlung rays were detected. The x-ray pulse widths were approximately 60 ns, and the time-integrated x-ray intensity had a value of approximately 50 μGy at 1.0 m from the x-ray source with a charging voltage of 80 kV. Angiography was performed using a film-less computed radiography system and gadolinium-based contrast media. In angiography of non-living animals, we observed fine blood vessels of approximately 100 μm with high contrasts.
© (2005) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Eiichi Sato, Yasuomi Hayasi, Rudolf Germer, Koji Kimura, Etsuro Tanaka, Hidezo Mori, Toshiaki Kawai, Takashi Inoue, Akira Ogawa, Shigehiro Sato, Kazuyoshi Takayama, and Hideaki Ido "Enhanced K-edge plasma angiography achieved with tungsten Kα rays utilizing gadolinium-based contrast media", Proc. SPIE 5920, Ultrafast X-Ray Detectors, High-Speed Imaging, and Applications, 592012 (21 September 2005); https://doi.org/10.1117/12.620212
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
X-rays

Tungsten

Angiography

Gadolinium

Plasma

Oxides

Ytterbium

Back to Top