Paper
6 May 2004 Ultrafast laser-based micro-CT system for small-animal imaging
Author Affiliations +
Abstract
We investigated ultrafast laser-based x-ray (ULX) source as an attractive alternative to a microfocal x-ray tube used in micro-CT systems. The laser pulse duration was in the 30 fs-200 fs range, the repetition rate in the 10 Hz - 1 kHz range. A number of solid targets including Ge, Mo, Rh, Ag, Sn, Ba, La, Nd with matching filters was used. We optimized conditions for x-rays generation and measured: x-ray spectra, conversion efficiency (from laser light to x-rays), x-ray fluence, effective x-ray focal spot size and spatial resolution, contrast resolution and radiation dose. Good quality projection images of small animals in single-and dual-energy mode were obtained. ULX generates narrow x-ray spectra that consist mainly of characteristic lines that can be easily tailored (by changing laser beam target) to the imaging task, (e.g. to maximize contrast while minimizing radiation dose). X-ray fluence can exceed fluence produced by conventional microfocal tube with 10 μm focal-spot hence allowing for faster scans with very high spatial resolution. Changing the laser target, and thus matching the characteristic emission lines with the investigated animal's thickness and composition, can be done quickly and easily. Using narrow emission lines for imaging, instead of broad bremsstrahlung, offers superior dose utilization and limits beam-hardening effects. Employing two narrow emission lines-above and below the absorption edge of a contrast agent-in quick succession allows dual-energy-subtraction micro-CT for imaging with a contrast medium. Dual-energy-subtraction is not practical with a microfocal tube. Compact, robust, ultrafast lasers are commercially available, and their characteristics are rapidly improving. We plan to construct a prototype in vivo ultrafast laser-based micro-CT system.
© (2004) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Andrzej Krol, Jean-Claude Kieffer, John Nees, Liming Chen, R. Toth, Bixue Hou, Russell E. Kincaid Jr., Ioana L. Coman, Edward D. Lipson, and Gerard Mourou "Ultrafast laser-based micro-CT system for small-animal imaging", Proc. SPIE 5368, Medical Imaging 2004: Physics of Medical Imaging, (6 May 2004); https://doi.org/10.1117/12.536190
Lens.org Logo
CITATIONS
Cited by 3 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
X-rays

Imaging systems

Pulsed laser operation

X-ray imaging

Spatial resolution

Ultrafast imaging

Ultrafast lasers

RELATED CONTENT


Back to Top