Paper
18 February 2004 Hyperspectral study of a 320x240 uncooled microbolometer array
Nicolas Guerineau, Bouchra Harchaoui, Marcel Caes, Alain Durand, Pierre Castelein
Author Affiliations +
Abstract
A test bench has been developed at the ONERA in order to measure the spectral responses of infrared focal plane arrays. This test bench can deliver hyperspectral cartographies with rather good resolutions (better than 16 cm-1) on large spectral ranges (from 1.3 μm to 20 μm). The principle of this test bench will be described and experimental results obtained with a 320x240 uncooled microbolometer array will be presented. As a conclusion, the ability of uncooled microbolometer arrays to make spectral measurements will be discussed.
© (2004) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Nicolas Guerineau, Bouchra Harchaoui, Marcel Caes, Alain Durand, and Pierre Castelein "Hyperspectral study of a 320x240 uncooled microbolometer array", Proc. SPIE 5249, Optical Design and Engineering, (18 February 2004); https://doi.org/10.1117/12.513729
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Microbolometers

Sensors

Spectroscopy

FT-IR spectroscopy

Cartography

Staring arrays

Fourier transforms

Back to Top