Paper
1 April 2003 Thermal management in high-power electronics cooled down using capillary pump
Boguslaw Wiecek, Tomasz Wajman, Mariola Felczak, Marek Berlinski
Author Affiliations +
Abstract
By using the evaporation of working fluid in the capillary it is possible to design and build cooling device, with high cooling effectiveness. This paper presents a preliminary cooling system integrated with electronic device., which is supported by evaporation and capillarity effects. A simplified modeling of conjugate heat transfer including evaporation using FLUENT package is discussed. The experiments for open and close loop capillary pomp are shown to compare and verify the measurements and simulation results.
© (2003) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Boguslaw Wiecek, Tomasz Wajman, Mariola Felczak, and Marek Berlinski "Thermal management in high-power electronics cooled down using capillary pump", Proc. SPIE 5073, Thermosense XXV, (1 April 2003); https://doi.org/10.1117/12.503889
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Capillaries

Liquids

Thermal modeling

Cooling systems

Electronic components

Electronics

Thallium