Paper
22 July 2003 In-vivo reflection spectroscopy measurements in pig brain during stereotactic surgery
Author Affiliations +
Abstract
Radio frequency (RF) lesioning in the human brain is a common surgical therapy for relieving severe pain as well as for movement disorders such as Parkinsonia. During the procedure a small electrode is introduced by stereotactic means towards a target area localized by CT or MRI. An RF-current is applied through the electrode tip when positioned in the target area. The tissue in the proximity of the tip is heated by the current and finally coagulated. The overall aim of this study was to improve the RF-technique and its ability to estimate lesion size by means of optical methods. Therefore, the optical differences between white and gray matter, as well as lesioned and unlesioned tissue were investigated. Reflection spectroscopy measurements in the range of 450-800 nm were conducted on fully anesthetized pigs during stereotactic RF-lesioning (n=6). Light from a tungsten lamp was guided to the electrode tip through optical fibers, inserted along a 2 mm in diameter monopolar RF-electrode. Measurements were performed in steps of 0-10 mm from the target in each hemisphere towards the entry point of the skull. In the central gray of the porcine brain measurements were performed both before and after the creation of a lesion. A total of 55 spectra were collected during this study. Correlation to tissue type was done using post-operative MR-images. The spectral signature for white and gray matter differs significantly for the entire spectral range of 450-800 nm. Pre- and post-lesioning reflection spectroscopy showed the largest differences below 600 and above 620 nm, which implies that lasers within this wavelength range may be useful for in-vivo measurements of tissue optical changes during RF-lesioning.
© (2003) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Johan Antonsson, Ola Eriksson, and Karin Wardell "In-vivo reflection spectroscopy measurements in pig brain during stereotactic surgery", Proc. SPIE 4958, Advanced Biomedical and Clinical Diagnostic Systems, (22 July 2003); https://doi.org/10.1117/12.476131
Lens.org Logo
CITATIONS
Cited by 5 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Tissues

Reflectance spectroscopy

Tissue optics

Spectroscopy

Brain

In vivo imaging

Electrodes

Back to Top