5 August 2002 1/f noise in Hg1-xCdxTe detectors
Author Affiliations +
Abstract
This paper investigates 1/f noise performance of Hg1-xCdxTe photovoltaic detectors when detector current is varied by changing detector area, bias, temperature and incident flux. Holding detector bias and temperature constant, measured 1/f noise current is proportional to the detector current. However for all detector areas measured, non-uniformity is observed in the noise current due to the varied quality of the detectors. Even for the λc=16μm , 4-μm-radius, diffusion-limited detectors at 78K held at reverse bias, the average and standard deviation in dark current is Id=9.76+/- 1.59x10-8A while the average and standard deviation in noise current at 1 Hz in a 1 Hz bandwidth is in=1.01+/- 0.63x10-12A. For all detector areas measured at 100 mV reverse bias, the average and standard deviation in dark current to noise current ratio is α D=in/Id=1.39+/- 1.09x10-5. Defects are presumed resident in the detectors that produce greater non- uniformity in the 1/f noise as compared to the dark current at 100 mV reverse bias. Noise was also measured as a function of temperature for two λ c=16 micrometers detectors from 55 K to 100 K. The average and standard deviation in the noise current to dark current ratio is αD=in/Id=2.36+/- 0.83x10-5 for the 26-micrometers -diameter detector and (alpha) D=1.71+/- 0.69x10-5 for the 16-micrometers -diameter detector. Dark and noise current were measured while changing the bias applied to a detector. In the diffusion-limited portion of the detector I-V curve, 1/f noise is independent of bias with α D=in/Id=1.51+/- 0.12x10-5. When tunneling currents dominated, αT=in/Id=5.21+/- 0.83x10-5. The 1/f noise associated with tunneling currents is a factor of three greater than the 1/f noise associated with diffusion currents. In addition, 1/f noise was measured on detectors held at -100 mV and 78 K under dark and illuminated conditions. The average noise to current ratio αD was approximately 1.5 x 10-5 for dark and photon-induced diffusion current. However, detector-to-detector variations exist even within a single chip. The two most important points are that non-uniformities in material/fabrication need to be addressed and that each individual type of current component has an associated 1/f noise current component, the magnitude of the relationship being different depending on the source current.
© (2002) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Arvind I. D'Souza, Maryn G. Stapelbroek, Stacy A. Masterjohn, Priyalal S. Wijewarnasuriya, Roger E. DeWames, and G. M. Williams "1/f noise in Hg1-xCdxTe detectors", Proc. SPIE 4721, Infrared Detectors and Focal Plane Arrays VII, (5 August 2002); https://doi.org/10.1117/12.478850
Lens.org Logo
CITATIONS
Cited by 2 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Sensors

Diffusion

Information operations

Temperature metrology

Diodes

Data modeling

Mercury cadmium telluride

RELATED CONTENT

Recent advances in Sofradir IR on II VI photodetectors for...
Proceedings of SPIE (February 13 2016)
Carrier transport mechanisms in narrow-gap photodiodes
Proceedings of SPIE (April 08 1999)
HgCdTe HDVIP detectors and FPAs for strategic applications
Proceedings of SPIE (October 10 2003)
HOT infrared detectors using MCT technology
Proceedings of SPIE (May 20 2011)
I V modeling of current limiting mechanisms in HgCdTe FPA...
Proceedings of SPIE (October 21 2004)

Back to Top