Paper
5 January 2001 Characterization of the focal quality of micron-size beams from x-ray mirrors and zone plates
Albert C. Thompson, James H. Underwood, Erik H. Anderson, Scott A. McHugo, Barry P. Lai
Author Affiliations +
Abstract
With the development of high quality x-ray mirrors and x-ray zone plates, the use of micron-size x-ray beams is growing rapidly. The size of the focal spot is frequently characterized by measuring either the transmitted or fluorescence counting rate as a knife edge is scanned through the beam; the full width half maximum (FWHM) of the derivative of this scan is often quoted as the 'resolution' of the system. Many systems have been built which are claimed to have a focal spot size of 1 micrometer2 or less. Unfortunately, this parameter does not give an accurate presentation of the focal quality of the beam. We have developed a test using a pattern of microfabricated 'dots' on a silicon wafer to measure the encircled energy in an x-ray focal spot as a function of radius. Using this test, we have found that focused x-ray beams frequently have a large, low intensity flare that is not represented in the beam profile as measured by the knife edge scan method. This flare can be produced by several factors including diffuse scattering from the mirror surfaces and higher orders of a zone plate. It can cause serious errors in when calculating elemental concentrations in heterogeneous samples. In addition, for micro-XAS experiments where the energy is scanned to identify the compound at a particular point, this flare may vary as a function of energy and therefore change the XAS spectra from a small particle in a complex sample.
© (2001) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Albert C. Thompson, James H. Underwood, Erik H. Anderson, Scott A. McHugo, and Barry P. Lai "Characterization of the focal quality of micron-size beams from x-ray mirrors and zone plates", Proc. SPIE 4145, Advances in X-Ray Optics, (5 January 2001); https://doi.org/10.1117/12.411640
Lens.org Logo
CITATIONS
Cited by 5 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
X-rays

Mirrors

Zone plates

X-ray optics

Luminescence

Silicon

Nickel

RELATED CONTENT

X-ray testing of silicon pore optics
Proceedings of SPIE (September 09 2019)
New x ray parallel beam facility XPBF 2.0 for the...
Proceedings of SPIE (July 11 2016)
Development of the ATHENA mirror
Proceedings of SPIE (July 06 2018)

Back to Top