Classically-designed X-ray image intensifiers, in which the primary converter of X-ray image (X-ray luminescent screen) is placed inside the vacuum space of the X-ray image intensifier, and the photocathode converting light image into electronic one is in optical contact with the primary converter, have decisively displaced a combined systems -- external X-ray luminescent screen, light-transmission optics, image intensifier -- from medical and industrial X-ray diagnostic devices since they possess essentially higher luminance amplification (higher X-ray-to-light image conversion coefficient) and higher signal-to-noise ratio. We have assumed that this conversion coefficient is determined as a ratio of luminance of light image at the output screen of the X-ray image intensifier (measured in cd/sq.m.) to intensity of the X-ray radiation at the input of the X-ray image intensifier, derived from the power of the exposure dose (in R/sec). When we analyzed an X-ray-to-light image conversion dependence, we found out that there is an inconsistency between a method of measuring the efficiency of this conversion and this dependence such that the power of the exposure dose determines absorption of X-ray radiation only in the air and can not be recalculated into absorption in components of the X-ray image intensifier. In order to solve these contradictions, in this paper we have considered spectral X-ray characteristics. We further developed assumptions that the spectral density of the power flow of bremsstrahlung X-ray radiation depends linearly on the quantum power of this radiation. We succeeded in relating this dependence with the power of the radiation exposure dose and in obtaining a family of spectral characteristics of bremsstrahlung X-ray radiation at different anode voltages of the X-ray tube for a certain exposure dose. The paper describes calculations of the total power flow of the bremsstrahlung X-ray radiation at the input of the X-ray image intensifier, calculations of absorption of this flow in the functional assemblies of the X-ray image intensifier -- in the input window made of different materials (glass, aluminum, beryllium, steel, and glass-carbon) and in the X-ray luminescent screen made of iodine cesium. We have calculated values for the conversion coefficient of the X-ray image intensifier on the whole.
© (1999) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
S. V. Kuklev and I. N. Zaidel "X ray-to-luminous image conversion in x-ray image converter tubes", Proc. SPIE 3516, 23rd International Congress on High-Speed Photography and Photonics, (22 June 1999); https://doi.org/10.1117/12.350480
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
X-rays

X-ray imaging

Image intensifiers

Absorption

Optical filters

Cesium

Iodine

RELATED CONTENT

New type of x ray wafer image intensifier with CsI...
Proceedings of SPIE (April 01 1993)
Effects of x ray spectrum on the NPS of a...
Proceedings of SPIE (April 25 2000)
The X-Ray Imaging System
Proceedings of SPIE (June 01 1972)
X-ray imaging using K-edge filters
Proceedings of SPIE (March 31 2011)

Back to Top