6 February 1997 Method for removing a majority of the error in PUV attenuation coefficients due to spectral drift in response with depth in the water column
Karen W. Patterson, Raymond C. Smith, Charles Rockwell Booth
Author Affiliations +
Proceedings Volume 2963, Ocean Optics XIII; (1997) https://doi.org/10.1117/12.266393
Event: Ocean Optics XIII, 1996, Halifax, Nova Scotia, Canada
Abstract
It is well known that UV radiation has the potential to cause significant damage to living organisms. Generally, shorter UV wavelengths have the potential to do exponentially more damage than longer wavelengths. Therefore, in calculating biological doses of radiation to marine organisms, even small spectral variations in recorded UV irradiance s can propagate into large errors. The PUV instrument made by Biospherical Instruments, Inc. is a commonly used filter-based radiometer used to measure UV radiation in the water column. it has long been known that he signal from the PUV becomes increasingly weighted by longer wavelengths with increasing depth in the water column. This is due to the increased attenuation of shorter UV wavelengths are compared to longer UV wavelengths in the water column. Presented here is a method of removing the majority of the spectral drift effect from the UV attenuation coefficients calculated from PUV data for biogenic waters. Chlorophyll and dissolved organic matter are allowed to vary independently with depth in a simple high-resolution spectral model for a variety of atmospheric total zone concentrations and solar zenith angels. To investigate the magnitude of errors and possible corrections, attenuation coefficients are calculated using the estimated PUV spectral response function for each channel and for 1nm model wavebands at 305, 320, 340 and 380 nm. The same process was conducted for clear water. Differences between the PUV-weighted attenuation coefficients and corresponding model attenuation coefficients for clear water and biogenic waters are used to develop a fairly simple method of eliminating a large portion of the spectral drift effect in attenuation coefficients calculated from PUV data.
© (1997) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Karen W. Patterson, Raymond C. Smith, and Charles Rockwell Booth "Method for removing a majority of the error in PUV attenuation coefficients due to spectral drift in response with depth in the water column", Proc. SPIE 2963, Ocean Optics XIII, (6 February 1997); https://doi.org/10.1117/12.266393
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Ultraviolet radiation

Signal attenuation

Water

Data modeling

Atmospheric modeling

Optical filters

Ozone

Back to Top