22 April 1996 Self-monitoring bond between steel and concrete
Xuli Fu, Deborah D. L. Chung
Author Affiliations +
Abstract
The bond strength and contact electrical resistivity between steel rebar and concrete were found to be linearly related, due to an interfacial phase of high volume resistivity that helps the boding. Acetone washing of the rebar increases the bond strength slightly and decreases the contact resistivity slightly, but does not affect the linear correlation, which provides a nondestructive method for bond strength assessment.
© (1996) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Xuli Fu and Deborah D. L. Chung "Self-monitoring bond between steel and concrete", Proc. SPIE 2719, Smart Structures and Materials 1996: Smart Systems for Bridges, Structures, and Highways, (22 April 1996); https://doi.org/10.1117/12.238853
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Resistance

Cements

Nondestructive evaluation

Interfaces

Oxides

Solids

Carbon

Back to Top