Abstract
X-ray optical systems based on Bragg-Fresnel multilayer components imaging an electron beam in a storage ring with micrometer resolution are presented. Design concepts are compared to alternative methods, and the aberrations and limits of Bragg-Fresnel multilayer optics are discussed. Experimental results of imaging the BESSY I source with sub 10 micrometer resolution are presented and the development of a compact Bragg-Fresnel multilayer telescope as a BESSY II standard beam monitor is described.
© (1995) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Karsten Holldack, Alexei I. Erko, and William B. Peatman "BESSY Bragg-Fresnel multilayer beam monitors", Proc. SPIE 2516, X-Ray Microbeam Technology and Applications, (25 September 1995); https://doi.org/10.1117/12.221675