Paper
28 March 1995 Infrared inspection of advanced army composites
Thomas S. Jones, Eric A. Lindgren, Charles G. Pergantis
Author Affiliations +
Abstract
The development of a field portable infrared inspection system, complete with infrared imager, data recording, digital image processing and analysis, and heat source for introduction of a thermal gradient, is described. The system provides excellent portability with minimal reliance on on-site electric power while maintaining excellent sensitivity to a variety of defects in typical U.S. Army composite structures. The portable system has demonstrated considerable flexibility in the nondestructive evaluation of a diverse assortment of composite structures for both aircraft and ground vehicle applications.
© (1995) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Thomas S. Jones, Eric A. Lindgren, and Charles G. Pergantis "Infrared inspection of advanced army composites", Proc. SPIE 2473, Thermosense XVII: An International Conference on Thermal Sensing and Imaging Diagnostic Applications, (28 March 1995); https://doi.org/10.1117/12.204857