8 May 1995 Performance and maintenance of storage phosphor plates and cassettes in digital radiography
Dorothy E. Steller Artz, Hamid Jafroudi, Matthew T. Freedman M.D., Seong Ki Mun
Author Affiliations +
Abstract
Projection radiography, based on the storage phosphor (SP) imaging medium is a promising but challenging technology. SP plates consist of phosphor particles that are embedded in a polymer binder like film and then coated onto a flexible backing. Image quality is dependent not only on the performance of the plate, but also on the handling of the plate-cassette combination by the user and the reading system itself. The imaging plates included in this study are the 14' X 17' and 10' X 12' standard plates (ST-V) used for general radiography and the high resolution (HR-V) plates used in mammography and for extremity exams. The cassettes or image plate holders correspond to the plate sizes with the 14' X 17' being lead backed. Recorded downtime of the reader due to plate-cassette operation failures, diagnostic image quality affected by plate artifacts, and plate and cassette replacement rates are for a period of twelve months. Records are maintained through a detailed maintenance log, the image reader's internal record for plate use, and the system's internal error log for physical malfunctions. By keeping a detailed log on maintenance and performance of specific system components, communication to the vendor has been timely and effective in solving equipment failures. Plate-cassette maintenance must be an integral part of overall quality control (QC) that includes technologist training, physical plant (clinical environment) changes, and routine evaluation of the operation and performance of CR system components. Quality control combined with equipment improvements have minimized the downtime of the system, image artifacts and replacement rates of plates and cassettes.
© (1995) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Dorothy E. Steller Artz, Hamid Jafroudi, Matthew T. Freedman M.D., and Seong Ki Mun "Performance and maintenance of storage phosphor plates and cassettes in digital radiography", Proc. SPIE 2432, Medical Imaging 1995: Physics of Medical Imaging, (8 May 1995); https://doi.org/10.1117/12.208380
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Image quality

Radiography

Chromium

Lead

Imaging systems

Mammography

Surface plasmons

Back to Top