22 May 1995 Evaluation of the PAR corneal topography system
Prateek Jindal, Susan Cheung, Amir Pirouzian, Richard H. Keates M.D., Qiushi Ren
Author Affiliations +
Abstract
The purpose of this study was to evaluate the raster photogrammetry based Corneal Topography System by determining: inter-operator variability, reproducibility of images, effects of defocused and decentered images, and the precision of data at different optical zones. 4 human cadaver eyes were used to study the inter-operator variability. To study the reproducibility of images, 3 human cadaver eyes and a test surface doped with flourescine (provided by PAR Vision Systems Corporation) were focused and their images taken four successive times. Defocused and decentered images were taken of 4 human cadaver eyes and four times of the test surface mentioned above. The precision of defocused/decentered cadaver eyes was evaluated at the following optical zones: 3 mm, 4 mm, 5 mm, and 6 mm. All human cadaver eyes used in the above experiments had their epithelial layer removed before imaging. Average inter-operator variability was 0.06 D. In reproducibility attempts, there was an average deviation of 0.28 D for the human cadaver eyes and 0.04 D for the test surface. The defocused and decentered test surface gave an average deviation of 0.09 D. Defocused and decentered cadaver eyes resulted in an average deviation of 0.52 D, 0.37 D, 0.24 D, and 0.22 D at optical zones of 3 mm, 4 mm, 5 mm, and 6 mm, respectively. The imaging method employed by PAR Vision Systems Corporation virtually eliminates inter-operator variability. The PAR Corneal Topography System's clinical usefulness, however, could be improved by improving the reproducibility of images, decreasing the sensitivity to spatial alignment, and increasing accuracy over smaller optical zones.
© (1995) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Prateek Jindal, Susan Cheung, Amir Pirouzian, Richard H. Keates M.D., and Qiushi Ren "Evaluation of the PAR corneal topography system", Proc. SPIE 2393, Ophthalmic Technologies V, (22 May 1995); https://doi.org/10.1117/12.209866
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Cornea

Computed tomography

Eye

Spherical lenses

Imaging systems

Raster graphics

Optical alignment

RELATED CONTENT

Cornea shape measurement
Proceedings of SPIE (August 01 1990)
Image processing in the compound eye of insects
Proceedings of SPIE (April 01 1993)
Automated specular microscopy in slit lamp
Proceedings of SPIE (June 07 2000)

Back to Top