Paper
16 September 1994 High-efficiency hard x-ray xenon gas proportional scintillation counter
Luis M. N. Tavora, Joaquim M. F. dos Santos, Carlos Alberto Na Conde
Author Affiliations +
Abstract
A large-volume (3 liters), xenon-filled, gas proportional scintillation counter with a curved grid and focusing rings was developed and tested with hard X-rays. The efficiency at 60 keV was calculated to be 64%. The experimentally measured energy resolution was observed to decrease from 6 to 5% when the X-ray energy was increased from 22.1 to 59.6 keV. Spectra are presented for the 241Am gamma rays and lanthanum K(alpha ) and B(beta ) X-rays. Spectra for the same K lines of erbium, praseodymium and tin are also presented for the detector with and without the focusing rings. These spectra show that the focusing rings increase the detection efficiency and improve the energy resolution. This effect is attributed to the increased electron collection in the scintillation region, to faster pulse rise times and to reduced electron attachment to impurities.
© (1994) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Luis M. N. Tavora, Joaquim M. F. dos Santos, and Carlos Alberto Na Conde "High-efficiency hard x-ray xenon gas proportional scintillation counter", Proc. SPIE 2280, EUV, X-Ray, and Gamma-Ray Instrumentation for Astronomy V, (16 September 1994); https://doi.org/10.1117/12.186806
Lens.org Logo
CITATIONS
Cited by 2 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Xenon

Sensors

Scintillation

Erbium

Gamma radiation

Hard x-rays

Praseodymium

RELATED CONTENT

NIST microcalorimeter arrays for the hard x ray and γ...
Proceedings of SPIE (January 01 1900)
High energy resolution plastic scintillator
Proceedings of SPIE (September 09 2016)
High-pressure xenon gamma-ray large-volume spectrometer
Proceedings of SPIE (October 18 1996)
Liquid Xe TPC with multistrip-type anode
Proceedings of SPIE (January 10 2003)

Back to Top