Paper
6 July 1979 Measurement Of The X-Ray-Induced Light Photons Emitted From Radiographic CaW04 Intensifying Screens
H. Roehrig, B. Lum, S. Nudelman, M. P. Capp, C. E. Dick
Author Affiliations +
Proceedings Volume 0173, Application of Optical Instrumentation in Medicine VII; (1979) https://doi.org/10.1117/12.957117
Event: Application of Optical Instrumentation in Medicine VII, 1979, Toronto, Canada
Abstract
For calcium tungstate intensifying screens employed in film-screen imaging systems, Coltman found that approximately 1000 light photons of average energy 2.7 eV were produced for each 50 keV x-ray absorbed. Of this number, he found that only about 55% are emitted from the output side of a 109 mg/cm2 screen. We have developed a method based on counting single photons to determine this number for various thicknesses of calcium tungstate screens. Monoenergetic x rays in the energy range from 17-69 keV produce upon absorption, a shower of individual photon pulses which are detected by a low noise photomultiplier. After amplification and discrimination against the noise background of the phototube, the resultant pulses are counted in a 70 MHz scaler or a 150 MHz counter. The detection system has a pulse resolving time of less than 15 ns. The data are then corrected for the quantum efficiency of the detector and normalized to the number of absorbed x rays which is determined in a separate experiment. For calcium tungstate screens with thicknesses of 30, 50, 86, and 123 mg/cm2, the average numbers of light photons emitted per absorbed x ray are measured for 8 x-ray energies between 17- and 69-keV. The values for 50 keV are less than the values found by Coltman. Studies of the causes of this discrepancy are in progress.
© (1979) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
H. Roehrig, B. Lum, S. Nudelman, M. P. Capp, and C. E. Dick "Measurement Of The X-Ray-Induced Light Photons Emitted From Radiographic CaW04 Intensifying Screens", Proc. SPIE 0173, Application of Optical Instrumentation in Medicine VII, (6 July 1979); https://doi.org/10.1117/12.957117
Lens.org Logo
CITATIONS
Cited by 3 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Photons

X-rays

Absorption

Electrons

Photomultipliers

Quantum efficiency

Silver

RELATED CONTENT

Characterization of DECam focal plane detectors
Proceedings of SPIE (July 22 2008)
Digital Method To Evaluate The Noise Of X Ray Image...
Proceedings of SPIE (December 26 1979)
Prediction Of Patient Doses In Diagnostic Radiology
Proceedings of SPIE (August 18 1980)
Multilayer x-ray-sensitive CCDs
Proceedings of SPIE (April 30 2002)

Back to Top