Presentation + Paper
24 June 2024 Advances in direct monochromatic monitoring for the DUV range
Author Affiliations +
Abstract
Monochromatic monitoring by intermittent measuring technique is established as a standard optical thickness control for thin films in box coaters since 2005. A newly developed set-up of the optical path was designed for the Syruspro 1100 DUV box-coater series. A deuterium lamp in combination with an achromatic lens system extends the monitoring capabilities to the UV range for wavelengths from 200nm up to 380nm. We present the hardware set-up and coating results for various DUV coatings.
Conference Presentation
(2024) Published by SPIE. Downloading of the abstract is permitted for personal use only.
Detlef Arhilger, Harro Hagedorn, and Alfons Zöller "Advances in direct monochromatic monitoring for the DUV range", Proc. SPIE 13020, Advances in Optical Thin Films VIII, 130200Q (24 June 2024); https://doi.org/10.1117/12.3021834
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Optical sensing

Ultraviolet radiation

Coating

Deep ultraviolet

UV optics

Lamps

Film thickness