Paper
19 October 2023 Study on inverter control under load disturbance based on repetitive and fuzzy PID methods
Chih-Chung Yang, Zejie Huang, Chia-wei Huang, Wei-Tai Hsu
Author Affiliations +
Proceedings Volume 12709, Fourth International Conference on Artificial Intelligence and Electromechanical Automation (AIEA 2023); 127094N (2023) https://doi.org/10.1117/12.2684882
Event: Fourth International Conference on Artificial Intelligence and Electromechanical Automation (AIEA 2023), 2023, Nanjing, China
Abstract
We explored the incorporated control method, which consists of repetitive control and fuzzy PID control, to tackle the problem of the prolonged transient period of the conventional PID feedback circuitry. With a Simulink model of the inverter circuit, we implement the two control schemes and evaluate the controller performances by introducing possible disturbance, a surge current or rectifier loading, at the load side. By comparing the output waveforms between our proposed control strategy and conventional PID control, our incorporated control method is favored due to the advantages of a smaller total harmonic distortion rate and a shorter regulation period.
© (2023) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Chih-Chung Yang, Zejie Huang, Chia-wei Huang, and Wei-Tai Hsu "Study on inverter control under load disturbance based on repetitive and fuzzy PID methods", Proc. SPIE 12709, Fourth International Conference on Artificial Intelligence and Electromechanical Automation (AIEA 2023), 127094N (19 October 2023); https://doi.org/10.1117/12.2684882