1.INTRODUCTIONForm stability of spaceborne optic is a crucial prerequisite needed to ensure the best possible image rendering. To this end low thermal expansion glass and/or ceramics are preferred for the manufacturing of these optics. Thus, the influence of local temperature gradients (resulting from e.g. periodic sun exposure) have only a minimal impact on the optical figure. Temperature variation is not the only root cause of deformations, effect such as compaction i.e. overall material shrinkage, induced by ionizing radiation are also mentioned. Independent investigations of radiation-induced compaction performed on the optical glass ceramic ZERODUR® led to very different results, differences by approximatively one order of magnitude have been observed between different authors, see [1][2][3][4][5]. It is of interest to note that the compaction properties have been investigated for large deposited doses. Indeed, all these researches vectored at the very beginning of the 80’s in a cold war context addressed the weapon effect, i.e. impact of very large dose deposition and high dose deposition rate. These operating conditions were far from the ones one could expect for a telescope optical mirror in a GEO orbit. The discrepancies observed in the magnitude of the different compaction laws can be attributed to the different approaches used (density measurement, induced vertex radius of curvature measurements) as well as to the mathematical approximations used in order to describe the deformation and/or the ionizing dose deposition field. In this work, we propose an experimental methodology in order to characterize with accuracy the compaction behavior of the glass ceramic ZERODUR® under ionizing radiations. In the first section we will discuss the main working strategy. The design of the coupons is then discussed in the following section; the geometrical limitation induced by the irradiation capability (homogeneity versus dose deposition rate) will be further detailed there. In the fourth section we describe the interferometric setup designed in order to characterize the sagitta induced by the dose deposited. At last we will describe the FEM based regression approach that will be used in order to derive the parameters defining the compaction law. 2.METROLOGICAL APPROACHThe influence of ionizing radiation on ZERODUR® can be made by considering a typical irradiation scenario that would be defined for a representative orbit over a given lifetime for a particular satellite. However, this approach would be by far too specific and only of little use for the error budgeting of specific missions. Another strategy would consist in deriving a phenomenological law binding the local optical deformation to the total ionizing dose deposition that could be afterward used by the optical engineers in order to estimate their overall error budget. Two main approaches can be considered for determining the phenomenology of the ionizing dose on the compaction of a material. The straightforward strategy consists in irradiating the material with some well-defined doses and measure the change of density observed. Albeit simple this approach can only be achieved at the required precision level (2 ppm) for large samples (approximatively 1002.5 ±2.5g), the homogeneous irradiation of such sample can be difficult and can only be achieved using gamma radiation due to its small absorbing cross section. This approach is the one chose by HIGBY, RADLEIN, however due to the smallness of the sample considered, these measures are marred with significant error bars. Another drawback of this methodology is that one does not characterize the change of optical figure observed, which is the quantity of interest in the astronomical community. Because of all these drawbacks, some authors have preferred characterizing the material compaction using an indirect optical approach, see [1][2]. Here the radiation induced sagitta of coupons (usually discs) were interferometrically measured. This approach supposes that the gradient of the deposited dose within the sample is well known. By combining this information with a bimetallic model, the authors were proposing a compaction law. The weakness of this approach lies in the determination of the dose profile within the samples (arbitrarily assumed to be at the edges of the solarized domain) combined with a crude bimetallic approach that simplifies a continuous dose-depth gradient into a stepwise constant function. The mathematics behind the derivations of the compaction law based on a bimetallic approach have also been debated; some misinterpretations of geometrical pre-form may have led to an overestimation of about one order of magnitude of the compaction law[5]. This work address the characterization of a compaction law by means of interferometry, the experimental measure of the radiation induced radius of curvature will be used for the fit of a phenomenological law. However, the estimation of the total ionization dose-depth within our material will be characterized by means of Monte Carlo simulations whose consistency will be cross-checked by means of Faraday cup measurements. The deformation field will not be described anymore by a thin-plate equation but by means of finite element methods in order to encompass all the possible effect that cannot be described using the Timoshenko thin plate approach (radial dependency of the strain field as well as limitation of the thin plate approximation). 3.EXPERIMENTAL PROCEDURE3.1CouponsThe definition of the coupon’s geometry has been intensively discussed as the geometry determines many very different aspects of this Design of Experiment (DOE). First, the diameter of the coupons must be compatible with the irradiation capability of the Physikalisch-Technische Bundesanstalt (PTB) our partner irradiation facility. A large surface can be homogeneously irradiated (radially) however with a small dose deposition/rate and consequently a large coupon will require a long exposure time in order to reach the targeted peak dose along its depth. The surface figure of the coupons is a determining factor for the unequivocal derivation of the irradiation induced Vertex Radius of Curvature (VRoC). The measured effect depends on both the diameter and also on the aspect ratio of the coupons. Manufacturing aspects must be taken into account together with the irradiation ones for the definition of the coupon’s geometry. Finally yet importantly, we must be able to measure properly the samples, this step also imposes some special conditions on the sample geometry. After several iteration steps, we collegially agreed in Ø=50 [mm samples having 2,0 and 5,0 mm thicknesses, these geometries were the most compatible with all the manufacturing, metrology and processing steps of this DOE. Because of the mechanical stress induced by the irradiations, some breakage could eventually be expected at high irradiation exposure. In order to minimize a priori these occurrences, we prepared our samples by grinding with the lowest grain sized diamond CNC tool available in routine use at SCHOTT Mainz, namely D25 (front and back side of the coupons) and D20 (wall and chamfer). The front and backsides of our samples are polished, however the walls and the chamfer will not. These latter surfaces are the most critical areas where the mechanical tension reaches its local maximum after exposure to irradiation; consequently, these areas must ideally be free of Sub Surface Damage (SSD). In order to remove these surface defect we acid etched our samples with a specifically designed etching solution (volume ratio mixture: 2 HF 38% : 1 HCl 37% : 6 H2O), during approximatively 10 min., to this etching exposure time corresponds a material removal of about 15 μm, i.e. 1,5 to 3 times the assumed size of our SSDs[6]. Meanwhile, in order to prevent any surface removal of the front or back side we masked our samples using acid resistant tape, see Figure 2. The aim of this work is to characterize the change of curvature induced by the ionizing irradiation, this curvature will be interformetrically measured. This method imposes also some constraint on the manufacturing of the coupons. Interferometric interference with the polished back surface reflection will very likely occur and the question of coating the front face of our coupons has been addressed. The back face of the coupons can of course be painted but painting and cleaning several times the back face would add successive steps that would increase the risk of mishandling1. Because of this, we rejected this option. Alternately, the samples can also have a small wedge in order to displace the interfering contribution of the reflected light. However, this approach would lead to unnecessary processing complexity and because of this we also discarded it. At the end, we finally decided to deposit a simple aluminum coating of the samples, technically the coating could be very easily achieved, the total reflection induced would prevent any back reflection and would greatly ease the interpretation of the data. Moreover, the reflective aluminum coating would drain the collected e- out of the sample through the metallic mount and would prevent any electrical breakdown within our samples. In addition to this, the conductance of the electrons through the coating also increases the reliability of the measurement of the deposited charges onto the samples, since the knowledge of this quantity sharpens our estimation of the deposited dose. 3.2SimulationsThe determination of the compaction is a very resource-demanding task, as it requires very precise before and after irradiation metrology regarding the pieces form, as well as a very cautious irradiation procedure. In order to maximize the success of these measures, we must beforehand estimate whether the surface figure induced in our samples could be measured. In other words, we must ensure already in the preliminary phase of the Design Of Experiments (DOE) that the orders of magnitude of the expected effects are compatible with the resolution of our metrological system. This step has been bridged by means of simulations. First, we estimated the expected dose-depth in our system for different electron energies and then, we investigated the estimated change of curvature induced in this samples by means of FEM approach. The irradiation simulations have been carried out with Geant4[7], to this end we used the version 10.3.3 of this software. The material under consideration is ZERODUR®, defined using the atomic database provided by the National Institute of Standards and Technology (NIST) combined with the chemical composition of ZERODUR®. The composition of surrounding material such as atmosphere, and metals involved along the irradiation line, namely titanium and stainless steel have all been described using the embedded NIST definition, namely G4_AIR, G4_TI and G4_STAINLESS-STEEL. The particle multiple scattering parameter has been defined to 1,0 mm, a limit where we reach a numerical convergence of the results (we validated this procedure on a previous system using the same particle accelerator but using different energies). At PTB the collimated e- beam are fired through vacuum onto a Ti sheet in order to scatter them over space. These scattered electrons are then travelling through atmosphere and will ionize the Device Under Test (DUT). The radial distribution of the collimated electrons is assumed to be normal with a full width at half maximum (FWMH = 2 mm), experimental estimation provided by the PTB. This stage of the irradiation has also be encompassed in our simulation. In order to achieve a good spatial accuracy, the target volume has been quantized into ΔV = Δx3 spatial element with Δx = 0.1 mm. A sketch of these simulations is given on Figure 3 below: For this DOE, we aim at disentangling the effect of the dose from the effect of the e- incident energy. Historically, all the previous works dealing with compaction described this phenomenon as being exclusively depending on the dose deposited and not of the kinetic energy of the incident particles. With this work, we evaluate the validity of this assumption by irradiating our samples with two different e- incident energies. The fraction of the e- contributing to the LEO and GEO ionizing radiations is mainly included in a [0;1.5] MeV energy range, see Figure 4, as a consequence we purposely considered energy in this range, namely 0,5 MeV and 1,5 MeV. The simulated dose depths at these two aforementioned energies are sketched on Figure 5 below: We considered irradiating the 2,0 mm thick samples with the E=0,5 MeV e- beam and the 5,0 mm thick samples with the E=1,5 MeV e- beam. For these energies, the penetration length of e- is about ½ of the thickness of the corresponding coupons, the strain field is then asymmetric through the depth therefore, a significant irradiation bending is expected2. The two sketched dose depth distributions of Figure 5 have then been reinjected into a FEM model (namely ABAQUS® software) representative of our coupons. The dose depth field has been converted into a strain field by means of a phenomenological compaction law previously determined in a joint work together with ESA ESTEC (60Co irradiation) and the PTB (density measures)3. In this FEM model we described the radiation induced stress relaxation of 2,0; and 5,0 mm thick coupons with 0,5 and 1,5 MeV. The rough estimations of the expected deformations are given on Figure 6: For both energies, the total dose deposited will be modulated by changing the radiation exposure time keeping all other parameters constant (positioning, e- firing frequency, etc…)· Remember that the deformation listed in the above table is only a guideline in order to estimate the orders of magnitude of the expected deformation. These values solely indicate whether the induced sagitta could be interferometrically measured with confidence and thus be helpful to us populating our DOE. The internal stress fields expected in for a dose deposition peak of 107 Gy have also been simulated see Figure 7: These stress estimations results made necessary removing the SSDs at the machining stage in order to mitigate any potential breakage. We clarify that these peak doses over these deposition length scales are not representative at all of any typical electron dose-depth profile over any traditional orbit. The corresponding induced curvature listed on Figure 6 are not representative of any deformations that one may expect over any space orbit. These coupons have been exclusively designed in order to characterize a compaction law for those who want to calculate the estimated deformation of their particular mirror design over their hypothesized irradiation scenario, which is depending on the satellite shielding, on the orbit, solar events as well as mission lifetime. 3.3Experimental e- irradiation flux characterizationThe coupons under consideration have been designed for a 0,5 and 1,5 MeV e- energy. The energy of the incident e- is an aspect that will define the dose-depth profile. Practically, the e- are collimated by magnetic field within the accelerator, then the collimated beam is scattered by a 50 μm thick Ti sheet. The scattered beam is not radially homogeneous but rather follows a normal distribution f(r; z): Where N is a normalization factor, σ(z) correspond to the standard deviation which is a function of the distance z between the scattering Ti sheet and the target, but also a parametric function of the thickness of the scattering metal sheet and the energy of the incident e- collimated in the beam. In order to characterize at best the dose-profile within our coupons (over the thickness but also radially) it is crucial to determine with accuracy the characteristics of the e- flux (in other words σ(z)). The detectors typically used for this task at the PTB (PTW Octavius 15000) regrettably are not sensitive enough for the energy considered. Since the penetration depth of e- is small, we are out of its sensitivity domain. In order to circumvent these difficulties, we performed a Geant4 Monte Carlo simulations of the irradiation line to estimate the expected radial distribution of the beam corresponding to the energy considered. Based on these simulations, we were able to propose a first guess regarding the distribution: that for a 500 keV energy we may expect a 90% radial homogeneity field over our coupons at a distance z ≈ 150mm. Since these estimations are purely based on computational approaches, they must be cross-checked. To this end, we designed very simple Faraday cups having different radii, namely R =15; 25; 40; 60 mm, see Figure 9: Some preliminary beam characterization tests will be carried out with these cups placed at a z = 150 mm distance from the canon with 500 keV e- incident electrons. The different charges collected for different disc radius keeping all the other irradiation parameter constant will give access to the experimental electron distribution. Practically, the charge collected on a metal discs of radius R at a distance z can be formally written : With dS = r. dr. dθ being a surface element (we took the usual cylindrical coordinates in order to describe our setup). If we now further develop the above expression we obtain: This above integral can be further simplified into: The first term of this expression, N *2π * σ(z)2 corresponds to the total amount of e- fired on the beam line during the test. Per design, this value will be kept constant over our experimentation as we will proposedly investigate all the different Faraday discs using the same irradiation parameters (i.e. also the total charge of fired e- per disc). Considering this, we can rewrite the expression of the collected charge: With C0 being the e- charge fired per test. The value C0 can be experimentally determined using the ICT (Bergoz Instrumentation) at the end of the beam line. Using all these measured charges we can then reconstruct the value σ(z) that characterizes the beam using either the ICT value and/or using different cup radius. The consistency of these measurements with the simulated collected charge fraction at a distance of 150 mm from the beam source for 500 keV electron energies presented on Figure 10 will validate our simulation approach as well as the hypothesized dose-depth distribution. 3.4Faraday mounting cupThe coupons will be held in a mount specially designed for the purpose of our experiments. This mount is made with a metal backplate and a metallic cover ring. The ZERODUR® samples will be loosely staked between the backplate and ring. The manufacturing tolerance of the cover ring have been precisely defined in order to minimize the surface masking but still preventing the coupons from falling. Furthermore, the small overlapping area will ensure the electrical contact between the coupons aluminum coating and the mount. The mount will be connected to a Coulombmeter for the in-situ monitoring of the irradiation experiment. The design of this Faraday cup is sketched on the Figure 11 below: The Faraday cups used for the irradiations are pictured on Figure 12. 4.ANALYTICAL PROCEDUREEvaluation of mirror surface radiation compaction at moderate commonly experienced in-orbit radiation doses requires substantial coupon metrology precision, and repeatability of the metrology setup. Measurement precisions of a few nanometers are required to address the expected magnitudes. Arizona Optical Systems (AOS) has established a surface metrology configuration to measure coupons using a HeNe (λ= 623.8-nm) Zygo Fizeau interferometer with a horizontal 150mm beam placed 150mm away from the coupon. Measurements are to be made before and after irradiation and compared, imposing that the interferometer and reference flat must maintained in stable hardware and software configurations covering this interval. Precautions for high accuracy surface metrology are imposed, including temperature control (±0.5-C) under laminar flow and vibration isolation. Measurements are made to a defined procedure, and to further ensure consistency, the same engineer makes the before and after irradiation measurements. The coupon is held in a Delrin fixture, ensuring that the part is perpendicular to the metrology beam, and marks establish azimuthal clocking of the coupon’s surface. Preliminary tests of surface measurement repeatability were made to qualify the process with on-hand, partially representative, coupons exhibiting a relatively crude surface accuracy ~ 320nm PV, or ~λ/2. Even with this large value of surface error, repeatability was 2.6-nm before and after removing and replacing the coupon, and 4.5-nm repeating the measurement decentered on the beam. Multiple measurements are made before and after, averaged for precision. Since the actual coupons to be irradiated are substantial better (~λ/6 or ~105-nm for the 2-mm thick coupons, ~ λ/20 or 32-nm for the 5-mm thick coupons), the repeatability, and ability to discern changes, is expected to be as much as 3x to 10x better than the evaluative result on the process qualification samples. Control samples, having not undergone irradiation, will accompany those irradiated, and be re-measured with these radiation exposed samples to establish the metrology uncertainty. 5.COMPACTION LAW DERIVATION5.1StrategyPrevious determination of the compaction using optical approaches were based on a rough estimation of the dose profile (LiMi estimation of the darkening limit of the glass) further coarsened by means of a bimetal analogy analysis. In order to catch most of the phenomenology of the compaction effect, we will proceed to the derivation of the dose depending phenomenological law by means of a least square algorithm. In this approach, we will minimize the discrepancies observed between the experimentally measured VRoC of our coupons and the numerically forecasted one by varying the parameters defining the phenomenological compaction law used into the FEM software. The Chi-squared function driving the fitting of the compaction law is defined: With:
Being based on FEM simulations, this procedure offers many advantages, i.e. we will consider our material mostly as a continuum and not as a composite. Moreover, we will not rely on the thin plate approximation whose validity depends on the radius/thickness ratio. The use of FEM may comprehensively address issues connected to some radial dependent dose distribution (remember that the mounting ring will shield the borders of the coupons). The correctness of the least squares algorithm has been tested on a model system where the experimental powers values have been substituted with FEM based values – reference data. We then started the least-square minimization algorithm using phenomenological compaction parameters, which were significantly different from the reference data. The graphical results summarizing the whole optimization process are provided on Figure 13. 5.2Power characterizationThe irradiations profile being mostly depth dependent and marginally radius depends we are mainly expecting an additional power contribution to the surface shape of our coupons. This power contribution can be characterized by means of the Zernike polynomial decomposition available on the interferometric software solution. In our present case, the coefficient of interest is the defocus term (radial degree n = 2, azimuthal degree m = 0, OSA/ANSI index j = 4): Where ρ stands for the normed radius of our optic, i.e. ρ ϵ [0; 1]. Formally, the Zernike approach aims at describing the surface profile G (ρ, φ) of an optic as being the outcome of an infinite sum of Zernike factor: Where am,n and bm,n are the weighting factors indicating the magnitude of the respective Zernike contributions and φ is the polar angle (polar coordinate system): Therefore, the a0,2 term is an indication of the magnitude of the optical power of our mirror. Formally, we can further refine our understanding of this term by performing a change of variables from cylindrical to Cartesian coordinates: For a surface shape mostly dominated by a spherical curvature term, we have a local elevation G following; With R being the VRoC of the optic, r the radius of the optic and ρ the local radial position. In this configuration we can see that the contribution to the defocus term scales like 1/R: By means of the Zernike decomposition, we can easily access to the radius of curvature or to the overall sagitta (SAG = r2/2R), these quantities can easily be derived from FEM structure simulations and will be used for the calculation of the merit function. 5.3Exclusive contribution of the irradiation to the change of VRoCPrior to the irradiation experiments, we expect some remnant polishing patterns and consequently some power profiles prior to any irradiation procedure. The characterization of the compaction is based on the characterization of the radiation induced power, this means that we must properly disentangle the power contribution due to the coupon polishing and the power contribution due to irradiation from the overall measured power contribution. Formally, the spherical contribution to the surface deformation can be written: If we know assume that the VRoC (R) is very large compared to the radius of the optic (r) we can approximate the above expression using a 1st order Taylor expansion into: If we now assume that the compaction is superimposing an additional contribution to the curvature we get: With The Zernike decomposition of experimental interferograms prior to the irradiation runs will provide the VRoC attributed to the polishing quality (Rpolishing), whereas the Zernike defocus contribution measured after irradiation will provide information about the cumulated contributions of the surface quality and irradiation induced compaction of the surface (Rpol.+com.). From these two experimental quantities, we can then derive the exclusive contribution of the compaction to the overall VRoC following: 6.CONCLUSIONS AND PERSPECTIVESThe measure of the compaction of a material is a complex task, this characterization can be made using two very different paths, either using the direct measurement of the density or using an indirect optical approach. The indirect measure of the density is by far the most sensitive strategy; however, it requires a deep understanding of the working hypotheses that bind the experimentally observed optical deformation to the phenomenological compaction law. In this publication, we show all the preparatory work readied for the determination of the compaction law by means of precise optical interferometry. This work will now enter in its final phase during the first half of 2021, samples prior to the irradiation will be measured as soon as a free irradiation slot at PTB will be available. Controlled interferometric measurements prior and after irradiations will be separated by a short time span in order to guarantee the stability of the metrological chain. REFERENCESBourrieau, J., Roméro, M.,
“ESA Spacecraft Mater. In Space Environment,”
275
–285
(1979). Google Scholar
Bourrieau, J.,
“Étude expérimentale sur l’irradiation par les particules à haute energie des miroirs utilisés dans le télescope radiomètre METEOSAT,”
Report N°2145/74/CG,
(1974). Google Scholar
Tsai, T., E., Higby, P., L., Friebele, E., J., Griscom, D. L., J. Appl. Phys.,
(62), 3488
–3490
(1987). https://doi.org/10.1063/1.339272 Google Scholar
Higby, P., L., Friebele, E., J., Shaw, C., M., Rajaram, M., Graham, E. K., Kinser, D. L., Wolff, E. G., J. Am. Ceram. Soc.,
(71), 796
–802
(1988). https://doi.org/10.1111/jace.1988.71.issue-9 Google Scholar
Davis, M., J., Fainberg, J.,
in Proceedings of SPIE, Optical Materials and Structures Technologies,
38
–49
(2003). Google Scholar
Leys, A., Hull, T, Carré, A., Westerhoff, T.,
“ICSO 2020 Paper session 250,”
Google Scholar
Allison, J.,
“Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment,”
(835), 186
–225
(2016). Google Scholar
SPENVIS,
“Space Environment Information System,”
Google Scholar
Notes[1] Paints are including organic binding agents that may decompose during the irradiations, the stability of the paint and the potential toxicity of the byproduct are not known. Because of this it is reasonable to assume beforehand that it may be required to paint several time the back face of the samples. [2] A 3,0 mm thick disc irradiated with 1,5 MeV would underwent a symmetric dose-distribution (symmetric with respect to the central plan). In this configuration, the strain field on the front and on the back side would partially annihilate. The resulting curvature would be small, even at high dose deposition. |