15 March 2019 Coherent multi-transducer ultrasound imaging in the presence of aberration
Laura Peralta, Alberto Gomez, Joseph V. Hajnal, Robert J. Eckersley
Author Affiliations +
Abstract
In order to improve resolution, transducers with larger aperture size are desirable in ultrasound imaging. However, the practical aperture size is limited. Inhomogeneities and aberrating layers cause phase errors restricting the improvements provided by large arrays. Recently, we have shown the feasibility of a fully coherent multitransducer ultrasound imaging system (CMTUS), formed by several ultrasound transducers that are synchronized and freely located in space. The transducer locations along with the average speed of sound in the medium are deduced by maximizing the coherence between backscattered echoes from targeted point-like scattereres in the common field of view of the transducers. An improved image is obtained through coherent combination of the multiple transducers acting as a single larger effective aperture. In this study, the behavior of CMTUS in the presence of aberration is further investigated with simulations. A parametric study is presented, in which the geometry of the system, defined by two linear arrays, and the presence of acoustic clutter are investigated. In this framework, typical image quality metrics - resolution, contrast and contrast-to-noise ratio - are evaluated. Results suggest that the imaging enhancement made by the CMTUS is limited by the location of the transducers in space. Based on image metrics, an optimal spatial location is proposed for a CMTUS formed by two linear arrays. In addition, results show that, in the presence of clutter, image quality diminishes at larger aperture sizes. Nevertheless, CMTUS successfully corrects the aberration effects, without degrading the gains made by the large effective aperture.
© (2019) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Laura Peralta, Alberto Gomez, Joseph V. Hajnal, and Robert J. Eckersley "Coherent multi-transducer ultrasound imaging in the presence of aberration ", Proc. SPIE 10955, Medical Imaging 2019: Ultrasonic Imaging and Tomography, 109550O (15 March 2019); https://doi.org/10.1117/12.2511776
Lens.org Logo
CITATIONS
Cited by 6 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Transducers

Ultrasonography

Imaging systems

Tissues

Point spread functions

Image resolution

Aberration correction

Back to Top