Paper
7 March 2019 High-energy quasi-CW 355-nm UV pulses generation from a diode-pumped sub-nanosecond Nd:YAG system
Author Affiliations +
Abstract
We demonstrated a 50 mJ, 100 Hz, 355 nm UV laser. The third harmonic generated in a diode-pumped 200 mJ, 500 ps Nd:YAG laser system centered at 1064 nm, which based on a master oscillator power amplifier configuration. The pulse duration and temporal shape from oscillator could be modulated by an Arbitrary-Waveform-Generator and an amplitude modulator. Two LBO nonlinear crystals were employed to second and third harmonic generation respectively. The UV laser system featured an approximately flat-top temporal distribution and a 2.5% energy stability (RMS) within 1 hour.
© (2019) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Xinlin Lv, Hongpeng Su, Yujie Peng, and Yuxin Leng "High-energy quasi-CW 355-nm UV pulses generation from a diode-pumped sub-nanosecond Nd:YAG system", Proc. SPIE 10896, Solid State Lasers XXVIII: Technology and Devices, 108960E (7 March 2019); https://doi.org/10.1117/12.2511399
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Ultraviolet radiation

Laser systems engineering

Nd:YAG lasers

Crystals

Modulation

Harmonic generation

Oscillators

RELATED CONTENT

180W at 1kHz, 532nm SHG from LBO crystals using high...
Proceedings of SPIE (February 28 2014)
High power lasers for gamma source
Proceedings of SPIE (February 17 2017)
Frequency-Doubled, Diode Pumped Nd:YAG Lasers
Proceedings of SPIE (July 16 1986)
Subpicosecond High-Brightness UV Laser System
Proceedings of SPIE (October 21 1986)

Back to Top