A comprehensive design of the Optical Bench has been developed, which includes all of the above mentioned functions and at the same time ensures manufacturability on the basis of hydroxide catalysis bonding, an ultrastable integration technology already perfected in the context of LISA's technology demonstrator mission LISA Pathfinder. Essential elements of this design have been validated by dedicated pre-investigations. These include the demonstration of polarizing heterodyne interferometry at the required Picometer and Nanoradian performance levels, the investigation of potential non-reciprocal noise sources in the so-called backlink fiber, as well as the development of a laser redundancy switch breadboard. |
I.INTRODUCTIONThe Laser Interferometer Space Antenna (LISA) is a cooperative space mission of ESA and NASA, aiming at the detection and observation of gravitational waves in a measurement band between 30 μHz and 1 Hz, in complement to ground-based gravitational wave detectors. LISA will be implemented in a constellation of three identical spacecraft at the corners of an equilateral triangle with a 5 million kilometer arm length, which is trailing Earth in a heliocentric orbit. Each spacecraft carries two free-falling reference targets, known as Proof Masses (PMs), defining the end points of the individual arms (Fig. 1). The passage of a gravitational wave causes minute fluctuations in the distance between the two proof masses of each arm, which are observed by heterodyne laser interferometry, that mutually links the three spacecraft in an active transponder scheme [1]. To allow for an independent technical optimization and decoupled verification of the individual functional elements of the metrology chain, the PM-to-PM interferometry on each interferometer arm is separated into two local and one long-arm measurement (Fig. 1): Relative motion of each PM with respect to its associated Optical Bench (OB) is detected by the PM Optical Readout (PM ORO) interferometer, while distance fluctuations between the two OBs of each interferometer arm are detected by the Science Interferometer. In this “strap-down architecture”, each OB thus serves as the common fiducial reference for on-ground combination of all interferometric signals in a procedure known as Time Delay Interferometry (TDI). This effectively synthesizes a huge virtual interferometer from the metrology data collected over the entire constellation. As illustrated in Fig. 2, each OB interfaces optically on one side with the Gravitational Reference Sensor, and on its other side with an afocal telescope. Inside a contamination control enclosure, the Gravitational Reference Sensor houses the associated Proof Mass, a 46 mm3 Gold-Platinum cube with a mass of 1.96 kg, which is electro-statically suspended in its rotational and lateral degrees of freedom. For optimization of the optical link budget on the long arm interferometry, the telescope provides an optical magnification of 80 to yield an external pupil of 400 mm diameter at the PM center of mass. It processes transmitted (TX) and received (RX) beam in opposite directions under a small point-ahead angle, required due to the non-negligible light travel time of approx. 16 s between the spacecraft [1]. Telescope Subsystem, Optical Bench, and Gravitational Reference Sensor are isostatically supported from a common interface ring to form the so-called Moving Optical Subassembly (MOSA), the main optical instrument of LISA. Each LISA spacecraft accommodates two identical MOSAs as part of the Optical Assembly, in which they can be individually rotated about a vertical pivot axis for precision pointing toward their respective remote counterpart. II.OVERVIEW OF OPTICAL BENCH FUNCTIONS AND REQUIRED PERFORMANCEThe LISA OB supports a total of 4 interferometers, which are based on polarizing heterodyne interferometry in Mach-Zehnder-like configuration (Fig. 3). A total of three slightly separated continuous-wave, narrow linewidth laser frequencies near 1064 nm are processed on the OB to generate the associated heterodyne beat signals:
In the Science Interferometer, the phase of the weak RX beam is detected by mixing it with a fraction of the TX beam. This particular choice, known as non-frequency swap configuration, makes the Science Interferometer robust against stray light from the high power TX beam, if operated in balanced detection. All local interferometry employs particular combinations of TX and LO beams, to realize the previously mentioned PM ORO, the PAAM Metrology for detection of piston noise in the TX path, as well as a reference phase measurement. Apart from these interferometers, the LISA OB includes two further types of detectors: an Acquisition Sensor aiding initial acquisition of the RX beam over a larger field of view, and a Power Monitor for observation and active stabilization of the TX optical power. For detection of beam pointing with Nanoradian precision, all interferometers on the LISA OB employ Differential Wavefront Sensing [4, 5]. This is realized by a spatially resolved phase measurement through the use of RF bandwidth Quadrant Photodetectors (QPDs). In order to decouple translation and tilt metrology as far as possible, dedicated imaging systems will be implemented in front of each QPD (Fig. 4). This approach, applied here to the best of our knowledge for the first time in an ultraprecise interferometric system, in particular minimizes pathlength measurement noise generated by pointing jitter of the measurement beams. Nonetheless, such pointing jitter, originating from residual attitude dynamics of the spacecraft and the Proof Mass, remains one of the significant noise sources within the LISA system. The allowable pathlength measurement noise for LISA is generally expressed in form of a single-link budget from local to remote proof mass on each arm, in direct correspondence to the strap-down concept introduced above. From the total single-link noise budget of where f is the frequency of the spectral noise component, the following allocations may be mapped to contributions from the Optical Bench Subsystem:
The allocations above for Long Arm Interferometry and Proof Mass Optical Readout refer to the pathlength measurement noise for static measurement beams, i. e. they do not include contributions from pointing jitter, which are covered by the remaining entries. The most dominant noise source is shot noise in the long arm interferometry, with a contribution of approx. . III.BREADBOARD STUDIESThe local Nd:YAG laser providing the TX beam is backed by an identical second unit, which is operated in cold redundancy. Each of these two lasers has a separate fiber connection to a Fiber Switching Unit (FSU) on the associated OB, which implements free beam redundancy switching between the two inputs. As illustrated in Fig. 5, this is realized by combining the output of the associated fiber collimators at a polarizing plate beam splitter, and correction of the polarization by rotation of a half wave plate, with subsequent polarization cleanup in a second non-absorptive polarizer. Essential novel features of the FSU have been investigated and validated by development and realization of dedicated breadboards. Beam collimation to an extremely low rms wavefront error of about λ/37 has been demonstrated by prototyping a so-called Fiber Mounted Assembly (FMA), and combining it with an aspherical collimating lens made from Fused Silica, which was precision aligned by use of a hexapod (Fig. 5). This result thus provides a proof of feasibility for achieving the required beam quality of λ/30 in the TX beam, which ensures compliance to the noise allocation for coupling of spacecraft attitude dynamics to TX piston in the far field, as quoted in the above noise budget. Wave plate rotation within the FSU is performed on the basis of piezo-activated slip-stick motion in a specifically developed FSU Actuator (Fig. 6), which has been fully qualified both with respect to sub-μradian pointing reproducibility and environmental load cases. A second type of mechanism installed on the OB is the Point-Ahead Angle Mechanism (PAAM), of which a fully validated prototype is illustrated in Fig. 7. While maintaining picometer pathlength stability within the measurement band, it allows a single-axis adjustment of the out-of-plane point-ahead angle, which exhibits a quasi-periodic variation with a one-year period due to orbital dynamics [1]. An active correction is required, since the variation with an amplitude of approx. ±6 μrad is significantly larger than the far-field beam width of 3.1 μrad FWHM. IV.EXPERIMENTAL VALIDATION OF METROLOGY PRINCIPLESThe metrology principles fundamental to the architecture of the Optical Bench as outlined above have been validated by a number of targeted experimental studies, of which a selection is addressed in the following. Since the performance of polarizing heterodyne interferometry can principally be limited by periodic non-linearities and other effects potentially not present in a polarization-insensitive setup, a particular focus has been a quantitative comparison between these two beam routing alternatives at representative performance levels. A specific interferometric setup was devised for this purpose, comprising a polarizing as well as a non-polarizing Mach-Zehnder interferometer observing effectively identical measurement paths, as illustrated in Fig. 8. The interferometer core was integrated on a Clearceram-HS® baseplate using hydroxide-catalysis bonding. Since the measurement performance curves depicted in Fig. 8 show no significant difference between the polarizing and the non-polarizing interferometer, and are all very close to a noise level of , the principal applicability of polarizing heterodyne interferometry for LISA is thus demonstrated. The Backlink Fiber transporting the TX light from the two OBs on board each spacecraft in opposite directions has to be fully reciprocal, i. e. the fiducial error resulting from a difference in the two counter-propagating optical paths is required to remain below within the LISA measurement band. This crucial property of the Backlink Fiber has been validated as schematically illustrated in Fig. 9. The setup employs again a quasi-monolithic, fully bonded interferometer on a Zerodur baseplate, which mimics the actual situation on the LISA OB as far as possible. Essential to demonstrating a reciprocity to picometer level in this experiment has been the application of so-called normalized straylight correction using balanced detection, as well as a subtraction of pathlength noise correlated with excessive environmental temperature fluctuations. Taking into account results from further on-going experiments, including in particular the principal validation of the interferometric imaging approach, it may be concluded that the basic metrology principles to be applied on the LISA OB are principally validated, so that in a next step an Elegant Breadboard of the LISA OB will be fully designed and realized on the basis of these. REFERENCESD. Weise, P. Marenaci, P. Weimer, M. Berger, H. R. Schulte, P. Gath, and U. Johann,
in ICSO Conference Proceedings,
(2008). Google Scholar
E.J. Elliffe, J. Bogenstahl, A. Deshpande, J. Hough, C. Killow, S. Reid, D. Robertson, S. Rowan, H. Ward, and G. Cagnoli,
“Hydroxide-catalysis bonding for stable optical systems for space,”
Class. Quantum Grav., 22 S257
(2005). Google Scholar
S. Ressel, M. Gohlke, D. Rauen, T. Schuldt, W. Kronast, U. Mescheder, U. Johann, D. Weise, and C. Brax-maier,
“Ultrastable assembly and integration technology for ground- and space-based optical systems,”
Applied Optics, 49
(22), 4296
(2010). Google Scholar
E. Morrison, B. J. Meers, D.I. Robertson, and H. Ward,
“Automatic alignment of optical interferometers,”
Applied Optics, 33
(22), 5041
(1994). Google Scholar
E. Morrison, B. J. Meers, D.I. Robertson, and H. Ward,
“Experimental demonstration of an automatic alignment system for optical interferometers,”
Applied Optics, 33
(22), 5037
(1994). Google Scholar
|