Paper
22 August 2017 Fabry-Perot cavity based on air bubble for high sensitivity lateral load and strain measurements
Author Affiliations +
Proceedings Volume 10453, Third International Conference on Applications of Optics and Photonics; 104532V (2017) https://doi.org/10.1117/12.2276342
Event: Third International Conference on Applications of Optics and Photonics, 2017, Faro, Portugal
Abstract
A Fabry-Perot air bubble microcavity fabricated between a section of single mode fiber and a multimode fiber is proposed. The study of the microcavities growth with the number of applied arcs is performed. The sensors are tested for lateral load and strain, where sensitivities of 0.32 nm/N and 2.11 nm/N and of 4.49 pm/με and 9.12 pm/με are obtained for the 47 μm and 161 μm long cavities, respectively. The way of manufacturing using a standard fusion splicer and given that no oils or etching solutions are involved, emerges as an alternative to the previously developed air bubble based sensors.
© (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Susana Novais, Marta S. Ferreira, and João L. Pinto "Fabry-Perot cavity based on air bubble for high sensitivity lateral load and strain measurements ", Proc. SPIE 10453, Third International Conference on Applications of Optics and Photonics, 104532V (22 August 2017); https://doi.org/10.1117/12.2276342
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Fabry–Perot interferometers

Optical microcavities

Sensors

Fabrication

Fabry–Perot interferometry

Multimode fibers

Sensor performance

RELATED CONTENT


Back to Top