Paper
19 October 2016 Study on the measuring distance for blood glucose infrared spectral measuring by Monte Carlo simulation
Xiang Li
Author Affiliations +
Proceedings Volume 10154, Advanced Optical Design and Manufacturing Technology and Astronomical Telescopes and Instrumentation; 1015422 (2016) https://doi.org/10.1117/12.2247404
Event: International Symposium on Optoelectronic Technology and Application 2016, 2016, Beijing, China
Abstract
Blood glucose monitoring is of great importance for controlling diabetes procedure and preventing the complications. At present, the clinical blood glucose concentration measurement is invasive and could be replaced by noninvasive spectroscopy analytical techniques. Among various parameters of optical fiber probe used in spectrum measuring, the measurement distance is the key one. The Monte Carlo technique is a flexible method for simulating light propagation in tissue. The simulation is based on the random walks that photons make as they travel through tissue, which are chosen by statistically sampling the probability distributions for step size and angular deflection per scattering event. The traditional method for determine the optimal distance between transmitting fiber and detector is using Monte Carlo simulation to find out the point where most photons come out. But there is a problem. In the epidermal layer there is no artery, vein or capillary vessel. Thus, when photons propagate and interactive with tissue in epidermal layer, no information is given to the photons. A new criterion is proposed to determine the optimal distance, which is named effective path length in this paper. The path length of each photons travelling in dermis is recorded when running Monte-Carlo simulation, which is the effective path length defined above. The sum of effective path length of every photon at each point is calculated. The detector should be place on the point which has most effective path length. Then the optimal measuring distance between transmitting fiber and detector is determined.
© (2016) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Xiang Li "Study on the measuring distance for blood glucose infrared spectral measuring by Monte Carlo simulation", Proc. SPIE 10154, Advanced Optical Design and Manufacturing Technology and Astronomical Telescopes and Instrumentation, 1015422 (19 October 2016); https://doi.org/10.1117/12.2247404
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Analytical research

Blood

Digital signal processing

Distance measurement

Glucose

Information science

Information technology

Back to Top