Near-infrared breast tomography calibration with optoelastic tissue simulating phantoms

[+] Author Affiliations
Shudong Jiang, Brian W. Pogue, Troy O. McBride, Marvin M. Doyley

Dartmouth College, Thayer School of Engineering, Hanover, New Hampshire?03755 E-mail: Shudong.jiang@dartmouth.edu

Steven P. Poplack

Dartmouth-Hitchcock Medical Center, Department of Diagnostic Radiology, Hanover, New Hampshire?03755

Keith D. Paulsen

Dartmouth College, Thayer School of Engineering, Hanover, New Hampshire?03755

J. Electron. Imaging. 12(4), 613-620 (Oct 01, 2003). doi:10.1117/1.1587153
History: Received Oct. 1, 2002; Revised Apr. 6, 2003; Accepted Apr. 23, 2003; Online October 22, 2003
Text Size: A A A

Clinical near-infrared (NIR) imaging is a diagnostic tool to quantify hemoglobin concentration and oxygen saturation within tissue. In order to remove system offsets and correct data acquired from the breast during clinical examination, a homogenous tissue-simulating phantom is routinely employed for system calibration. In this study, both hard resin and soft silicon-based materials were used to make calibration phantoms with different physical sizes, shapes, elasticity, and optical properties. Using these calibration phantoms, the imaging performance of two different fiber optic configurations was tested. Images from a patient with a biopsy-confirmed ductal carcinoma tumor were also used to determine the effect of calibration object choice upon real tissue image reconstructions. Softer silicon-based calibration phantoms were found to mimic the elastic properties of human breast tissue quite well with an elastic modulus that could be tailored between 100 and 230 KPa. These values agree with estimates of breast tissue elasticity and we have found that these phantoms provide an optimal model for mimicking breast tissue, while having homogeneous properties, which are ideal for calibration and validation of the system. In this study, the performance of the imaging system with colocalized source and detector optical fibers (transceiver system) yielded better image quality than the system with separated-source detector fibers. In vivo imaging of the ductal carcinoma revealed increased total hemoglobin within the tumor. © 2003 SPIE and IS&T.

© 2003 SPIE and IS&T

Citation

Shudong Jiang ; Brian W. Pogue ; Troy O. McBride ; Marvin M. Doyley ; Steven P. Poplack, et al.
"Near-infrared breast tomography calibration with optoelastic tissue simulating phantoms", J. Electron. Imaging. 12(4), 613-620 (Oct 01, 2003). ; http://dx.doi.org/10.1117/1.1587153


Tables

Access This Article
Sign in or Create a personal account to Buy this article ($20 for members, $25 for non-members).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging & repositioning the boxes below.

Related Book Chapters

Topic Collections

PubMed Articles
Advertisement
  • Don't have an account?
  • Subscribe to the SPIE Digital Library
  • Create a FREE account to sign up for Digital Library content alerts and gain access to institutional subscriptions remotely.
Access This Article
Sign in or Create a personal account to Buy this article ($20 for members, $25 for non-members).
Access This Proceeding
Sign in or Create a personal account to Buy this article ($15 for members, $18 for non-members).
Access This Chapter

Access to SPIE eBooks is limited to subscribing institutions and is not available as part of a personal subscription. Print or electronic versions of individual SPIE books may be purchased via SPIE.org.