SPECIAL SECTION ON MATHEMATICAL MODELING, STATISTICAL ESTIMATION, AND INVERSE PROBLEMS

Bayesian estimator for positron emission tomography imaging using a prior image model with mixed continuity constraints

[+] Author Affiliations
Ching-Han Hsu

Chang Gung University, School of Medical Technology, 259 Wen-Hwa 1st Road, Kwei-Shan 333, Tao-Yuan, Taiwan, Republic of China

J. Electron. Imaging. 9(3), 260-268 (Jul 01, 2000). doi:10.1117/1.482744
History: Received Sep. 15, 1999; Revised Nov. 15, 1999; Accepted Dec. 15, 1999
Text Size: A A A

Abstract

A novel image prior with mixed continuity constraints is proposed for the Bayesian positron emission tomography image reconstruction of human brains. Assume that a human brain can be partitioned into four tissue classes: gray matter, white matter, cerebral spinal fluid, and partial volume. And each partial volume image voxel consists of an arbitrary mixture among pure tissues. The brain image is then modeled as a piece-wise smooth function through a Gibbs prior with the image intensity of each region governed by the thin-plate energy function. We apply first and second order edge detection techniques to estimate region boundaries, and then categorize these boundaries based on the resulting edge maps. Rather than use the binary processes representing region boundaries such as weak-membrane or weak-plate (WP) models, we adopt a controlled-continuity approach to influence boundary formation. We refer to this model as a modified (WP) model with controlled continuity. We present the results of a computer simulated phantom study in which partial volume effects are explicitly modeled. Results indicate that we obtain superior region of interest quantitation using this approach in comparison to a partial volume correction method that has previously been proposed for quantitation using filtered back-projection image. © 2000 SPIE and IS&T.

© 2000 SPIE and IS&T

Citation

Ching-Han Hsu
"Bayesian estimator for positron emission tomography imaging using a prior image model with mixed continuity constraints", J. Electron. Imaging. 9(3), 260-268 (Jul 01, 2000). ; http://dx.doi.org/10.1117/1.482744


Figures

Tables

Access This Article
Sign in or Create a personal account to Buy this article ($20 for members, $25 for non-members).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging & repositioning the boxes below.

Related Journal Articles

Related Book Chapters

Topic Collections

PubMed Articles
Advertisement
  • Don't have an account?
  • Subscribe to the SPIE Digital Library
  • Create a FREE account to sign up for Digital Library content alerts and gain access to institutional subscriptions remotely.
Access This Article
Sign in or Create a personal account to Buy this article ($20 for members, $25 for non-members).
Access This Proceeding
Sign in or Create a personal account to Buy this article ($15 for members, $18 for non-members).
Access This Chapter

Access to SPIE eBooks is limited to subscribing institutions and is not available as part of a personal subscription. Print or electronic versions of individual SPIE books may be purchased via SPIE.org.